background image

INPUT

Connect RCA ourput cables from the headunit 

to OKUR digital amplifiers’ RCA Input.

OUTPUT

Is used when connecting multiple amplifiers 

POWER & PROTECTION INDICATOR

Power LED - Green-lit shows normal operation 

Protect LED - RED-lit shows general malfunction, 

faulty connection or thermal protection 

GAIN ( 6V ~ 0.2V )

Matching the output voltage of the headunit's 

RCA line-outs to OKUR amplifiers’ input section.

SUBSONIC FILTER ( 10Hz ~ 50Hz @ 24dB/Oct )

Control the high Pass point for the speaker outputs

to eliminate extreme low frequencies that can damage

your subwoofers.

BASS BOOST ( 0~9dB @ 45Hz )

It boosts the bass 0 ~ 9dB

REMOTE LEVEL CONTROL PORT

This port is for connecting remote gain level control.

LOW PASS FILTER ( 35Hz ~ 250Hz @ 24dB/Oct )

Controls the low pass point for the speaker outputs.

PHASE ( 0 ~ 180 degree )

It control phase from 0 ~ 180 degree

OUTPUT MASTER / INPUT SLAVE 

OUTPUT MASTER / INPUT SLAVE connection makes 

OKUR digital amplifiers as daisy chain connection 

to 2 ohm.  

+12V ( POWER CONNECTION )

This must be connected to the fuse positive terminal 

( +12V ) of the battery. 

Recommended wire is 4 gauge for 

A7

750.1 & 

A7

1100.1 

and 0 gauge for 

A7

1500.1, 

A7

2000.1, 

A7

2500.1

check the battery voltage

GND ( GROUND CONNECTION )

It is connected to the Negative or ground cables of 

the Vehicle. 

Recommended wire is 4 gauge for 

A7

750.1 & 

A7

1100.1 

and 0 gauge for 

A7

1550.1, 

A7

2000.1, 

A7

2500.1 

REM ( REMOTE )

It is connected to sw12V with a Trigger cable 

coming from the head unit

SPEAKER OUTPUTS 

it connects amplifier’s terminals to subwoofer speakers.

Minimum speaker wire is 12 guage. 

Minimum impedance is 1 ohm for single unit. 

Linked connection’s minimum impedance is 2 ohm.

2. OKUR AMPLIFIER’S CONTROL & CONNECTION.

2-1. OKUR digital monoblock amplifiers

Summary of Contents for OKUR A7125.4OKUR A7300.2OKUR A7750.1OKUR A71100.1OKUR A71500.1OKUR A72000.1OKUR A72500.1

Page 1: ...nual Instalation Instructions Owners Manual Due to continuous improvement of the product the Specifications are subject to change without notice A775 4 A7125 4 A7300 2 A7750 1 A71100 1 A71500 1 A72000...

Page 2: ...8 5 16 Volts 20Hz 250Hz 100dB 250 6V 0 2V Variable 35Hz 250Hz Vairable 0 9dB Variable 10Hz 50Hz Variable 0 180 degree Yes Yes Yes 1 ohm for single unit 2 ohm for linked 1 2 OKUR 2 and 4channel class...

Page 3: ...the speaker outputs PHASE 0 180 degree It control phase from 0 180 degree OUTPUT MASTER INPUT SLAVE OUTPUT MASTER INPUT SLAVE connection makes OKUR digital amplifiers as daisy chain connection to 2 oh...

Page 4: ...cting multiple amplifer to the same RCA signal GND GROUND CONNECTION It is connected to the Negative or ground cables of the Vehicle Recommended wire is 4 gauge for A7300 2 A775 4 A7125 4 REM REMOTE C...

Page 5: ...mage to amplifier and audio system A775 4 A7125 4 A7300 2 A7750 1 A71100 1 and A71500 1 are designed to use minimum 4 gauge power and ground cables A72000 1 A72500 1 are designed to use minimum 0 gaug...

Page 6: ...als on each speaker Strip 3 8 of insulation from the end of each cable and twist the cables strands together tightly Make sure there are no stray strands that might touch other cables or terminals and...

Page 7: ...R CONNECTION DIAGRAM 2 8 2 ohms 8 2 ohms OKUR 4CHANNEL AMPLIFIERS SPEAKER CONNECTION DIAGRAM 1 8 2 ohms 8 2 ohms 8 2 ohms 8 2 ohms CAUTION A7300 2 A775 4 A7125 4 Amplifiers minimum impedance is 2 ohms...

Page 8: ...8 4 ohms OKUR 4CHANNEL AMPLIFIERS SPEAKER CONNECTION DIAGRAM 2 8 2 ohms 8 2 ohms OKUR 4CHANNEL AMPLIFIERS SPEAKER CONNECTION DIAGRAM 3 8 2 ohms 8 2 ohms 8 2 ohms 8 2 ohms 8 4 ohms...

Page 9: ...ter amplifier to the head unit and set its output master and input slave switch to output master position Step 2 Connect the master and slave amplifiers in daisy chain Rca jack as shown in the diagram...

Page 10: ...CAUTION A7750 1 A71100 1 A71500 1 A72000 1 A72500 1 Amplifiers Linked minimum impedance is 2 ohms Remote turn on 12V Ground BATTERY Ground MASTER AMPLIFIER SLAVE AMPLIFIER 8 2 ohms...

Page 11: ...edance for all Class D mono amplifiers is 1 ohm for single unit and 2 ohm for linked operation 3 If the OKUR amplifiers are shut down due to overheat Reset by turning off the remote input and alowing...

Page 12: ...This limited warranty does not extend to units that have been subjected to misuse abuse neglect or accident Products that in DB DRIVE s judgment shows evidence of having been altered modified abused o...