INTRODUCTION 

 

Theory of Operation 

The Daytronic Model 4500™ is an industrial grade "intelligent" panel 
instrument that measures, displays, records, controls and utilizes 
computer/plc interfacing of process sensors for on-line production and 
testing of manufactured parts and components for the purpose of high 
speed quality verification and control. A configurable, real-time display 
and touch screen interface allows for easy monitoring and interfacing in 
stand-alone operations. The unit includes an external communications 
port(s) that allow data retrieval and supervision by external computers 
and controllers.  
 
The Model 4500 contains two separate microprocessors subsections for 
the purpose of data flow, control and interfacing. The front-end section, 
referred to as the DSP, scans, data converts and manages the analog 
measurement data at a sampling rate of 10KHz per analog and 
mathematical calculated data channels. The interface section, referred to 
as the Host, manages the communications, display, touch and other 
interfacing capabilities of the instrument.  
 
The DSP manages the A/D sampling, linearization, engineering units 
conversion, mathematic calculation channels, limit control, command 
control and DAC outputs of the 4500 unit. The DSP operates 
independently from the Host subsection to maintain data integrity and 
timing while posting data results and control parameters to the Host 
section.  
 
The Host subsection supervises the data from the DSP for the purpose 
of operator display, touch control and computer interfacing of the 4500. 
Areas such as the touch screen, display, RS-232 command interface, 
memory management and optional items are the responsibility of the 
Host section of the 4500. With this type of separated, managed 
assignments between areas 

– DSP for obtaining and publishing the data 

and the Host to manage the data flow 

– the 4500 has the ability to 

constantly run without interruption of the data for the purpose of stand-
alone control and operation interaction.

 

 
 

Summary of Contents for 4500

Page 1: ...Model 4500 Quick Reference Guide Daytronic Corporation 2566 Kohnle Drive Miamisburg Ohio 45342 Telephone 1 800 668 4745 or 937 866 3300 Fax 937 866 3327 www daytronic com...

Page 2: ...quipment and installations and who has received safety training on the hazards involved Qualified personnel who work on or near exposed energized electrical conductors must follow applicable safety re...

Page 3: ...tilis et entretenu uniquement par un personnel qualifi Selon le National Electrical Code une personne est qualifi e si elle conna t bien la construction et l utilisation de l quipement ainsi que les d...

Page 4: ...tions or practices that could harm the Model 4500 its data other equipment or property NOTE statements call attention to specific information Symbols The following International Electrotechnical Commi...

Page 5: ...y connection to a power line Before each use inspect all cables for breaks or cracks in the insulation Replace immediately if defective Turn off the power supply to the Model 4500 Before connecting to...

Page 6: ...ide has been reviewed and is believed to be entirely reliable however no responsibility is assumed for any inaccuracies All material is for informational purposes only and is subject to change without...

Page 7: ...PREFACE Warning 1 Safety Summary 3 Statements and Notices 5 INTRODUCTION Theory of Operation 7 DSP Section Data Scan Function 8 Host Section Operator and Interfacing Management 9 BASIC SETUP Quick Set...

Page 8: ...analog and mathematical calculated data channels The interface section referred to as the Host manages the communications display touch and other interfacing capabilities of the instrument The DSP ma...

Page 9: ...culation channels are updated at 10KHz rate including limit monitoring Four DAC Analog Output Data Channels Updated at 10KHz rate the digital to analog output channels are available to the user to cre...

Page 10: ...any or a combination of the following elements for the page display data channels real and calculated logic bits bar graph representation of the data channels trend graphs of the data channels touch...

Page 11: ...10 Daytronic Model 4500 Quick Reference Guide This page intentionally left blank...

Page 12: ...instrument Refer also to the appropriate 5D manual for more information the 5D manuals are available from Daytronic or visit the website at www daytronic com NOTE The sensors do not need to be connect...

Page 13: ...ress OK and then Accept the new calibration settings When calibration is complete Exit the setup screens until the Home page appears NOTE Use a stylus or a blunt object like a pencil eraser when worki...

Page 14: ...ot assignment page 7 Upon return to the Instrument Editor Menu press the Edit a channel setup button This is where the editor will apply known information to match the input sensor to the 5D condition...

Page 15: ...e page 9 Upon return to the Home page press Calibration Set up a 5D module Select the appropriate module icon box that user would like to calibrate It is suggested to have a live input from the sensor...

Page 16: ...n of the input following the instructions displayed If not press OK Exit to return to the Home page 12 From the Home page press the Meter icon to monitor the Analog Input values for proper operation a...

Page 17: ...s with the instrument and verify the Model and Type of the unit Once communication between the 4500 and UtiliPAC410 is successfully established the main menu appears 14 Observe the instrument data by...

Page 18: ...s The 5D manuals are available from Daytronic or visit the website at www daytronic com 5D30 AC Excitated LVDT 4 5 or 6 wire 16 to 2500mv V 5D40 Frequency full scale ranges from 200Hz to 400KHz 5D64 D...

Page 19: ...I command and response syntax Analog Outputs Four 4 Live originating from the B output of the 5D module 0 to 5Vdc with 20 over range Four 4 Digitally controlled analog outputs of 0 to 10Vdc originatin...

Page 20: ...19 Daytronic Model 4500 Quick Reference Guide This page intentionally left blank...

Reviews: