(12)
Limiter
Dual-Band Limiter
: Adjust, optimize, save, recall.
a)
Threshold:
Adjust the limiter threshold, 0~-12dB, step: 0.1dB
b)
Attack:
Adjust limiter’s “attack time”. This controls the time taken to attenuate signals over the
threshold to the specified threshold level. Range: 1/5/10/20/100ms
c)
Release:
Adjust limiter's “release time”. When signal is below threshold level, this controls the
time taken to restore back to original level. Range: 60/120/240/480/1000/2000ms
d)
Frequency:
The crossover frequency point between the 2 bands: Band 1 (Low Frequency) &
Band 2 (High Frequency).