Daytime BC16 Operating Manual Download Page 9

To set the end of the pause, press the S3 button and hold it down until the status LED starts to 
blink  red.  Then  press  the  S1  button  to  specify  the  number  of  hours  (e.g.  pressing  zero  times  = 
00:00 / pressing six times = 06:00). Then release the buttons. The red status LED will then return 
to green after a short time; this indicates that normal operations have resumed. 

 

Note: To disable the pause feature, set the start and end of the pause to 00:00. First press S2 until 
the  status  LED  illuminates  red.  Then  release  S2  (S1  is  not  pressed,  so  the  time  is  set  to  0:00). 
Wait until the status LED is green. Press the S3 button until the status LED illuminates red. Then 
release S3 and wait until the LED turn green.  

 

8. Factory settings: 

The BC16 has factory default settings and can be reset at any time as follows: 

1.  Disconnect the power supply. 
2.  Press and hold both the S2 and S3 buttons. 
3.  Connect the power supply. 
4.  The  Status  LED  acknowledges  the  reset  to  factory  settings  by  rapidly  flashing 

red/green. 

5.  Release buttons S2 and S3. 

Stored default settings: 

 

Sunrise start: 

08:00 

 

Sunset start: 

21:00 

 

Pause: 

Disabled  

 

Brightness of daylight: 

100% 

 

Brightness of night light:  0% 

 

Transition period:  

Stage 3 (5 minutes) 

 

Note:  When  the  factory  default  settings  are  loaded,  the  internal  clock  is  set  to  00:00  hours  and 
must then be correctly set to the real time. 
 

9. Time-lapse function (special mode):

 

The  BC16  has  a  time-lapse  mode  that  can  be  used  for  testing  purposes  or  for  checking  your 
specified values. When it is enabled, the clock runs several times faster and shows the specified 
light program in fast motion in 60 seconds. Instead of the standard transition periods used in the 
normal  operating  mode,  shorter  (only  a  few  seconds)  transition  times  are  used.  This  can  be 
enabled  or  disabled  during  operations.  When  the  time-lapse  function  is  disabled,  the  clock 
resumes running with  its previously set time, so that it does not need to be set. You can enable 
and disable the time-lapse function as follows: 

Press the S1 button briefly five times in succession in order to switch the time-lapse function ON 
or OFF. 

If the time-lapse function is enabled, the status LED flashes alternately red/green. Buttons S2 and 
S3 are disabled in time-lapse mode. 

Summary of Contents for BC16

Page 1: ...Operating Manual Basic Control BC16 single channel for matrix...

Page 2: ...with our daytime lighting Notice warning and safety symbols The European Standard prescribes the use of the following symbols for specific situations they are not intended to unsettle the user They a...

Page 3: ...ent water condensation from running along the cable to the converter or outlet Notice Make sure that all cables have no kinks in them are not routed over sharp edges cannot be jammed or snagged and ca...

Page 4: ...ight Can be dimmed manually in real time Internal 24 hour clock with about 15 minutes of power reserve Shapely high end enclosure with comfort control buttons Professional Plug Play connector system m...

Page 5: ...onds The internal clock has a power reserve it can run for an additional 15 minutes after a shut down or after a power outage The lights are turned off during this time A quick periodic flashing of th...

Page 6: ...one daytime matrix light with an output of max 240 watts Example with one converter one two way distributor optionally available and two daytime matrix lights with a total output of max 240 watts 2 P...

Page 7: ...gnal that the clock is still running The first 10 minutes are signalled with green flashes After 10 minutes the LED will flash red unit the power reserve is empty The device will switch immediately ba...

Page 8: ...period the duration of the change from daylight to night light stored and vice versa can be adjusted at any time during normal operations To set this press the S2 button briefly five times in successi...

Page 9: ...S2 and S3 Stored default settings Sunrise start 08 00 Sunset start 21 00 Pause Disabled Brightness of daylight 100 Brightness of night light 0 Transition period Stage 3 5 minutes Note When the factor...

Page 10: ...hour Press and hold S2 until the status LED turns red Then select hours with S1 for example Press zero times 00 00 press twice 02 00 Your settings will be saved automatically after a short interval of...

Page 11: ...thout connecting cables 90 x 40 x 26 mm Length of connecting cables primary secondary approx 90 mm including plug and socket Weight approx 80 g Operating voltage 24 VDC safety extra low voltage Max lo...

Page 12: ...ounds for a complaint within this warranty period please fill out and submit the enclosed warranty card to your nearest daytime dealer daytime a trademark of Sapelloh 51 31606 Warmsen Germany Tel 49 0...