Daytime BC16 Operating Manual Download Page 10

10. Brief overview of the settings  

Setting 

Procedure 

 
Time 

 

Press and hold S1. Select the hour with S2 and the minutes with S3 (in 5-minute 
increments). 

 
for example: 20:15: press S2 20 times (= 20:xx); press S3 3 times (= XX:15) 
 
Always set the hours before setting the minutes, since the minute value is set to 00 after 
the hours are set! 

 

Your settings will be saved automatically after a short interval of no pressed buttons. 

 

 
Start of sunrise and sunset

 

(the hour) 

 

Press and hold S1 for about 8 seconds until the status LED illuminates red. Then 
release S1. Use S2 to select the number of hours for the sunrise start, and S3 for the 
sunset start.   
 

for example: Press zero times = 00:00; press 6 times = 6:00; press 21 times = 21:00 
 
You  must  always  specify  both  of  these  time  points.  However,  if  only  one  time  point  is 
changed, the other time point will automatic be set to 0:00! 
 

Press S1 to apply/save settings

 

 

 
Brightness 
Daylight and night light 

(0 – 100%) 

 

Simultaneously press S2 and S3 to select day/night light. Dim with S2 (-); brighten 
with S3 (+). 
 
Apply/save with S1. Or settings will be saved automatically after a short interval of 
no pressed buttons. 
 

 
Start of pause

 (full hour) 

 

Press and hold S2 until the status LED turns red. Then select hours with S1.  

 
for example: Press zero times = 00:00; press twice = 02:00. 
 

Your settings will be saved automatically after a short interval of no pressed buttons. 

 

 
End of pause 

(full hour) 

 

Press and hold S3 until the status LED turns red. Then select hours with S1.  

 
for example: Press zero times = 00:00; press five times = 05:00. 
 

Your settings will be saved automatically after a short interval of no pressed buttons. 

  

 
Transition period  

(6 stages)                                          

 

Press S2 briefly five times. LED displays red "blink code". Buttons S2 and S3 for 
selecting one of the 6 stages: 

 
1x blinking = without transition time / 4x blinking = transition time approx. 15 min 
2x blinking = transition time approx. 1min / 5x blinking = transition time approx. 30min 
3x blinking = transition time approx. 5min / 6x blinking = transition time approx. 60min 
 

Press S1 to apply/save settings

 

 

 
Factory settings 

 

Disconnect power supply > Press and hold S2 + S3 > Connect power supply > Status 
LED flashes rapidly alternately red/green > Release buttons 

 
Note: When the factory default settings are loaded, the internal clock is set to 00:00 hours 
and must then be correctly set to the real time. 
 

 
Time-lapse

 

 

Press S1 quickly 5 times in succession to enable/disable the time-lapse function. 
The status LED flashes alternately red/green when this function is enabled. 

Summary of Contents for BC16

Page 1: ...Operating Manual Basic Control BC16 single channel for matrix...

Page 2: ...with our daytime lighting Notice warning and safety symbols The European Standard prescribes the use of the following symbols for specific situations they are not intended to unsettle the user They a...

Page 3: ...ent water condensation from running along the cable to the converter or outlet Notice Make sure that all cables have no kinks in them are not routed over sharp edges cannot be jammed or snagged and ca...

Page 4: ...ight Can be dimmed manually in real time Internal 24 hour clock with about 15 minutes of power reserve Shapely high end enclosure with comfort control buttons Professional Plug Play connector system m...

Page 5: ...onds The internal clock has a power reserve it can run for an additional 15 minutes after a shut down or after a power outage The lights are turned off during this time A quick periodic flashing of th...

Page 6: ...one daytime matrix light with an output of max 240 watts Example with one converter one two way distributor optionally available and two daytime matrix lights with a total output of max 240 watts 2 P...

Page 7: ...gnal that the clock is still running The first 10 minutes are signalled with green flashes After 10 minutes the LED will flash red unit the power reserve is empty The device will switch immediately ba...

Page 8: ...period the duration of the change from daylight to night light stored and vice versa can be adjusted at any time during normal operations To set this press the S2 button briefly five times in successi...

Page 9: ...S2 and S3 Stored default settings Sunrise start 08 00 Sunset start 21 00 Pause Disabled Brightness of daylight 100 Brightness of night light 0 Transition period Stage 3 5 minutes Note When the factor...

Page 10: ...hour Press and hold S2 until the status LED turns red Then select hours with S1 for example Press zero times 00 00 press twice 02 00 Your settings will be saved automatically after a short interval of...

Page 11: ...thout connecting cables 90 x 40 x 26 mm Length of connecting cables primary secondary approx 90 mm including plug and socket Weight approx 80 g Operating voltage 24 VDC safety extra low voltage Max lo...

Page 12: ...ounds for a complaint within this warranty period please fill out and submit the enclosed warranty card to your nearest daytime dealer daytime a trademark of Sapelloh 51 31606 Warmsen Germany Tel 49 0...

Reviews: