background image

 

16 

M2A-FM User Manual 

 

DaySequerra – One Year Limited Warranty 

 

DaySequerra warrants this product to be free from defects in materials and workmanship to its original owner for 
one (1) year from the date of purchase.  DaySequerra will repair or replace such product or part thereof that upon 
inspection by DaySequerra, is found to be defective in materials or workmanship subject to conditions contained 
herein. 

DaySequerra products are sold worldwide, through a network of authorized DaySequerra dealers and distributors. 
This Warranty is for the sole benefit of the original purchaser of a DaySequerra product, purchased directly from 
an authorized DaySequerra dealer or distributor, is restricted to such original purchaser, and shall not be 
transferred to a subsequent purchaser of the product. Proof of purchase in the form of a bill of sale or receipted 
invoice substantiating that the product was purchased directly from an authorized DaySequerra dealer or 
distributor and is within the warranty period must be presented to obtain warranty service. Removal or alteration 
of the original DaySequerra serial number from a product automatically renders that product warranty null and 
void. 

A Return Authorization Number must be obtained from DaySequerra in advance of return. Parts or product for 
which replacement is made shall become the property of DaySequerra. The customer shall be responsible for all 
costs of transportation and insurance to and from the DaySequerra factory, and all such costs will be prepaid. 

DaySequerra shall use reasonable efforts to repair or replace any product covered by this limited warranty within 
thirty days of receipt. In the event repair or replacement shall require more than thirty days, DaySequerra shall 
notify the customer accordingly. DaySequerra reserves the right to replace any product that has been 
discontinued from its product line with a new product of comparable value and function. 

This warranty shall be void in the event a covered product has been damaged, or failure is caused by or 
attributable to acts of God, abuse, accident, misuse, improper or abnormal usage, failure to follow instructions, 
improper installation or maintenance, alteration, or lightning, power fluctuations and other incidental or 
environmental conditions.   Further, product malfunction or deterioration due to normal wear is not covered by this 
warranty. 

DAY SEQUERRA DISCLAIMS ANY WARRANTIES, EXPRESSED OR IMPLIED, WHETHER OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE, EXCEPT AS EXPRESSLY SET FORTH 
HEREIN. THE SOLE OBLIGATION OF DAY SEQUERRA UNDER THIS LIMITED WARRANTY SHALL BE TO 
REPAIR OR REPLACE THE COVERED PRODUCT, IN ACCORDANCE WITH THE TERMS SET FORTH 
HEREIN. DAY SEQUERRA EXPRESSLY DISCLAIMS ANY LOST PROFITS, GENERAL, SPECIAL, INDIRECT 
OR CONSEQUENTIAL DAMAGES WHICH MAY RESULT FROM BREACH OF ANY WARRANTY, OR 
ARISING OUT OF THE USE OR INABILITY TO USE ANY DAY SEQUERRA PRODUCT.

 

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitation on how 
long an implied warranty lasts, so the above limitations and exclusions may not apply to you.  This warranty gives 
you specific legal rights, and you may also have other rights that vary from state to state.  DaySequerra reserves 
the right to modify or discontinue, without prior notice to you, any model or style product.  If warranty problems 
arise, or if you need assistance in using your product contact: 

DaySequerra 
154 Cooper Road, Building 902 
West Berlin, NJ 08091 
 
For more information, please call 856-719-9900, visit 

www.daysequerra.com

 or email us at 

[email protected]

 

 

 

Day Sequerra   154 Cooper Rd. S902   W. Berlin, NJ 08091   Voice 856-719-9900   [email protected]   www.daysequerra.com 

                      |                            

                        

 |       

|      

|      

|      

Summary of Contents for M2A-FM

Page 1: ...M2A FM Analog FM Modulation Monitor User Manual Ready ...

Page 2: ...ck extensive listening field testing and careful refinement In the event that you encounter any technical or operational difficulties with this or any DaySequerra product please feel free to contact us at 856 719 9900 Our office hours are from 9 to 5 ET Monday through Friday Or you can email your questions to info daysequerra com Also please remember to visit our website www daysequerra com for wa...

Page 3: ...2011 All logos and trademark used herein are the property of their respective owners Specifications subject to change M2A FM Revision D M2A FM Features Brilliant accurate bargraph metering of analog programming Multi function vacuum florescent display VFD shows decoded RBDS Precision metering of FM Pilot and SCA injection levels MPX output lets you connect external SCA demodulators Six dry contact...

Page 4: ...re updates Introduction The DaySequerra M2A FM is the world s best analog FM monitor complete with world wide tuning and de emphasis settings The M2A FM measures your analog signal with digital accuracy insuring that readings will remain stable and reliable over time Selectable measurement integration times let you control peak reading for maximum modulation The M2A FM includes a sensitive yet sel...

Page 5: ...Key Features FM ANTENNA INPUT Industry standard 75 ohm F connector FM HIGH LEVEL INPUT Industry standard 50 ohm BNC connector 7VAC Pk Pk maximum ANTENNA HIGH LEVEL INPUT SELECT User selected for antenna or high level input STEREO ANALOG OUTPUTS Balanced 4dBm for 100 analog modulation DIGITAL AUDIO OUTPUT 110 ohm transformer isolated for all broadcasts IEC320 POWER INLET 120VAC with integrated fuse...

Page 6: ...any shipping damage If damage is found or suspected please notify the carrier at once and then contact your dealer The DaySequerra M2A FM is shipped in one carton which contains the M2A FM unit an AC power cable a TorxTM T 8 L key and this User Manual We strongly encourage you to save the shipping carton and shipping materials supplied with your M2A FM They are specially designed to properly prote...

Page 7: ...ch selects manual FM tuning controlled by UP and DN controls Holding switch in for 5 seconds forces monitor into Forced Mono mode MONO is displayed on 2nd line of VFD Blue arrow LED illuminates when mode is active Holding on startup allows you to select between 100kHz and 200kHz tuning and 75 and 50 uS de emphasis PRESETS The M2A FM has capability to recall 20 preset or stored FM stations using th...

Page 8: ...f Push SELECT to continue R F C A R R I E R L O S S S E T O F F If SET is selected submenu for Level threshold with LOW MED and HIGH options is displayed next LOW option sets RF carrier loss threshold for approximately 10µV 25dBf MED option sets RF carrier loss threshold for approximately 100µV 45dBf and HIGH option sets RF carrier loss threshold for approximately 3KµV 75dBf Use UP and DN switches...

Page 9: ...tches to toggle the setting and highlight the desired option Push SELECT switch to continue A U D I O L E V E L L O W M E D H I G H Submenu for Alarm Delay with 30 60 120 and 240 second options is displayed next Use UP and DN switches to toggle the setting and highlight the desired option A L A R M D E L A Y 3 0 6 0 1 2 0 2 4 0 S Push SELECT switch to save and increment the menu to the next alarm ...

Page 10: ...ration menu select OFF to set this alarm function to off Push SELECT to continue P I L O T P R E S E N T S E T O F F If SET is selected submenu for Alarm Delay with 30 60 120 and 240 second options is displayed next Use UP and DN switches to toggle the setting and highlight the desired option A L A R M D E L A Y 3 0 6 0 1 2 0 2 4 0 S Push SELECT switch to save and increment the menu to the next al...

Page 11: ...for Modulation Level is displayed next Use UP and DN switches to vary the setting between 100 125 Set the Modulation to the desired trigger level Push SELECT to continue M O D U L A T I O N L E V E L 1 0 5 If SET is selected submenu for Alarm Delay with 30 60 120 and 240 second options is displayed next Use UP and DN switches to toggle the setting and highlight the desired option A L A R M D E L A...

Page 12: ... e all front panel controls are inhibited except for PANEL LOCK switch analog and digital audio outputs continue VFD alternates between displaying FRONT PANEL LOCKED and normal display for tuned station Blue arrow LED illuminates only when switch is being pushed or when mode is active Holding PANEL LOCK switch for 5 seconds un blanks all front panel controls and indicators and returns M2A FM to no...

Page 13: ...dicates relative RF signal level received at the antenna connector on the M2A FM rear panel A minimum of 5 RF signal strength segments must be illuminated indicating 65dBf for accurate demodulation and carrier level measurements Headphones Recessed screwdriver control adjusts headphone output level on recessed TRS jack Default set at the factory is 7 0dBm 0 1VAC Pk Pk SCA and AM Measurements Overv...

Page 14: ...N switches can be used to select another subcarrier frequency to be measured or the Carrier Modulation Select switch can be used to exit the Sub Pilot injection level measurement mode If the UP and DN switches are used to select another subcarrier frequency to be measured in this case the 57kHz SCA the process is identical to that described above In this example the VFD now indicates the 57 kHz su...

Page 15: ... Peak Alarm 15 14 11 M2A FM Ethernet Port Option The M2A FM Ethernet Port Option offers DaySequerra s Remote Dashboard TM software a proprietary PC based application and an Ethernet interface to provide remote control monitoring for FM broadcasts as well as a robust alarm panel Please email your M2A FM serial number and contact information to support daysequerra com or register your unit on our we...

Page 16: ... customer accordingly DaySequerra reserves the right to replace any product that has been discontinued from its product line with a new product of comparable value and function This warranty shall be void in the event a covered product has been damaged or failure is caused by or attributable to acts of God abuse accident misuse improper or abnormal usage failure to follow instructions improper ins...

Reviews: