10
M2A-FM User Manual
•
If “SET” is selected, submenu for “Alarm Delay” with “30”, “60”, “120” and “240” second
options is displayed next. Use UP and DN switches to toggle the setting and highlight the
desired option.
A L A R M D E L A Y
3 0 > 6 0 < 1 2 0 2 4 0 S
Push “SELECT” switch to save and increment the menu to the next alarm function.
Alarm Output 4 – Pilot Present
•
Pilot Present alarm is factory set to alarm for a 19kHz pilot injection level of less than 2%.
Highlight desired “SET” or “OFF” option using UP and DN switches to toggle the setting.
Select “SET” to set this alarm and continue with alarm configuration menu; select “OFF”
to set this alarm function to off. Push “SELECT” to continue.
P I L O T P R E S E N T
>
S
E
T
<
O
F
F
•
If “SET” is selected, submenu for “Alarm Delay” with “30”, “60”, “120” and “240” second
options is displayed next. Use UP and DN switches to toggle the setting and highlight the
desired option.
A L A R M D E L A Y
3 0 > 6 0 < 1 2 0 2 4 0 S
Push “SELECT” switch to save and increment the menu to the next alarm function.
Alarm Output 5 – RBDS Data Loss
•
RBDS Data Loss
alarm is factory set to activate based on data in Radio Text field.
Highlight desired “SET” or “OFF” option using UP and DN switches to toggle the setting.
Select “SET” to set this alarm and continue with alarm configuration menu; select “OFF”
to set this alarm function to off. Push “SELECT” to continue.
R B D S D A T A L O S S
>