iLC2ST User Manual 

performing a pause/resume or reset of the infinite average value in both the application and on 
iLC2ST. 
 

4. 

Per channel Short Term Average:

  Shows the short average of each channel on the graph.  A 

heavy vertical line shows where the target value on the iLC2ST is set.  Each channel’s reading 
is also shown in numerical form to the right of the graph, with the graph lines and the numerical 
value changing color to show the level of loudness. 

 

5. 

Status Bar:  

Three status boxes show more data that is collected from the unit.  The left box will 

display unit fault status.  Clicking on the box will display the history of faults captured by the 
Remote Dashboard software.  The center box shows Mix Monitor status of the selected tab.  
Clicking on the box will display the Mix Monitor history for that tab.  The right box displays the 
Remote Dashboard communication status.  Clicking on this box, while connected to an iLC2ST 
unit, will display additional information about that unit. 

 

 

Log Files 

   

The Remote Dashboard software’s main objective is to log your program audio loudness and have 
those measurements available for compliance verification. A new log file is created each hour and runs 
from x:00:00 to x:59:59. A new file will be created immediately if any data log options are changed. 
 
By default, measurement data log files are saved in the “logfiles” folder under the main Remote 
Dashboard application installation folder. A full day of logging each available data field once per second 
will consume approximately 27MB of storage space. Storage of files onto flash drives or other 

solid 

state storage 

devices is not recommended due to very frequent data writes the application makes and 

the “write endurance” of these devices. 
 
Logs are saved in Tab delimited format and can be imported into any database application that 
supports the importation of external data. Log files may also be imported into Microsoft Excel or 
Microsoft Access. The first line of each log file contains a column header that labels what data is 
contained within that column. 
 
 

Log File Import Example 

 

This brief procedure will demonstrate how to import the log file data into Microsoft Excel and render 
some simple graphs of the data. This procedure has only been verified to work in Microsoft Excel 
versions 2000, 2003 or 2007. 
 

1.

 

Open Microsoft Excel. In Excel 2007, click on the Data tab, and then click the Text button under the Get 
External Data group. In Excel 2000 or 2003, click on the Data menu, click Get External Data and then 
click Import Text File. 

2

 

The Import Text File box will appear. On the bottom of the window, click the Files of type drop down 
box and select All Files (*.*). Then, navigate to the location that the log files are stored in 
and select the appropriate log file. Double click on the file name or select the file and press the 

 

Import button. 

3

 

The Text Import Wizard will start. Press the Finish button, as no values on these pages will 
need to be modified. 

4

 

The Import Data box will appear and ask where in the Excel sheet the data should be inserted. 

Summary of Contents for iLC 2ST

Page 1: ...iLC 2ST User Manual...

Page 2: ...uerra has been building broadcast quality products since 1989 The technology developed for the ILC2ST and all of our products has evolved through a process of user feedback extensive listening field t...

Page 3: ...uerra Corp Copyright 2011 All logos and trademark used herein are the property of their respective owners Specifications subject to change iLC2ST User Manual Revision A 1 for firmware 4 01 01 ILC2ST K...

Page 4: ...ice Information The DaySequerra ILC2ST contains no user serviceable components inside the unit Please contact DaySequerra for repair and upgrade information In the event that your unit needs to be ret...

Page 5: ...GPI Alarms DB 9 female connector 0 5VDC TTL 2 DayPart Inputs per channel Alarm at fault Outputs Ethernet Remote Dashboard 10 100 BASE T for field software updates logging and remote control Remote Das...

Page 6: ...cturer could void the user s authority to operate this equipment The user should use only shielded and or grounded cables to combat sources of interference Environmental Preservation Efforts This equi...

Page 7: ...pressure of an acoustical signal Neither of these measurements although widely accepted provides accurate indications of how viewers will perceive the loudness of the audio programming The DTS NLM alg...

Page 8: ...ng standard ITU R BS 1770 produces results known as LKFS that are referenced to a dB FS scale While certain Leq x measures match more closely to human loudness perception than traditional SPL or RMS m...

Page 9: ...h a single tone of a certain energy level and more tones are added with equal energy in the critical bands the total signal energy is kept constant regardless of the number of tones If changing from o...

Page 10: ...he HEIMDAL multi band model did not achieve the complexity of cochlear modeling as shown by J Allen the method had the lowest error compared to any preceding loudness models Nielsen Skovenborg 2004 De...

Page 11: ...two NEMA5 15P to IEC320 C13 AC power cables We strongly encourage you to save the shipping carton and shipping materials supplied with your ILC2ST They are specially designed to properly protect your...

Page 12: ...supply UPS to protect against power surges and low voltage conditions For maximum redundancy connect each power supply to a separate UPS on different power circuits ILC2ST may be combined with other d...

Page 13: ...last programmed state Rear Panel AES INPUTS Two 75 BNC connectors will accept the AES3 digital audio stream For ILC2ST to work properly the following channel inputs must be maintained 1 2 Left and Rig...

Page 14: ...died the relay will open Output 2 Relay 2 is Normally Open Upon a fault condition the relay will close When the failure is remedied the relay will open Input 1 Momentary voltage detected on this port...

Page 15: ...ple rate of extracted audio is converted to 48 kHz 24 bit resolution regardless of the source material and is available as AES audio at ILC2ST s output jacks Programming Menu Loudness Meter System If...

Page 16: ...Pause Resume Infinite Average icon Selecting this icon while on the Home Screen and pressing SELECT will pause the Infinite Average Pressing SELECT once more will resume calculations for determining t...

Page 17: ...y input 11 Stereo B Pause Resume Infinite Average icon Selecting this icon while on the Home Screen and pressing SELECT will pause the Infinite Average Pressing SELECT once more will resume calculatio...

Page 18: ...ess Control Icon Select to enter Loudness control submenu Auto Infinite Average Turns the infinite average on an off when an inbound audio signal is below the selected threshold The default threshold...

Page 19: ...FS Relative Level is READ ONLY For A 85 ATSC it is N A R128 EBU 10 LUFS ARIB TR B32 10 LKFS Block Period is READ ONLY For A 85 ATSC it is N A R128 EBU and ARIB TR B32 400ms Meters Additional meters ca...

Page 20: ...ers long using A Z and 0 9 Press ENTER then use the rotary knob to scroll to the desired character To select the character Press ENTER When complete press ENTER again to save the entry Press BACK or H...

Page 21: ...iLC2ST will get timing from the 1 2 BNC Input c 3 4 iLC2ST will get timing from the 3 4 BNC Input d Internal Processing is synchronized with the iLC2ST internal clock e External Processing is synchro...

Page 22: ...l configuration Will only be present if the HD SDI I O module is installed HD SDI Mapping Menu Figure 8 HD SDI Mapping Menu Screen Display For iLC2ST to make precise loudness measurements the audio ch...

Page 23: ...hoices of letters A Z 0 9 and _ underscore and press ENTER to move on to the next field Turning the knob again will start to scroll through the choices for the next letter or pressing ENTER accepts th...

Page 24: ...he current state of the GPIO inputs The four fields of the displayed status represent each input 1 4 respectively Alarms Alarm sets GPO 1 2 to alert the user of AES Lock Loss and Hardware Failures Cha...

Page 25: ...n and is configured for the correct input port CRC Error ILC2ST has encountered a CRC mismatch error in the audio stream This may be due to a corrupted or invalid channel status bit sent by the source...

Page 26: ...o correction will be applied For example A setting of 4dB indicates that audio content can range 4 dB above the Target Level before attenuation is applied Content arriving louder than 4 dB above the T...

Page 27: ...low frequencies high or low frequency noise does not become over emphasized Compressor Threshold A compressor is present to catch any short term loudness peaks which aren t fully captured by the atta...

Page 28: ...e times The secondary Compressor is set close to the target to reduce transients Frequency compensation has been turned off to allow equal spectral gain to be applied to the lowest of input signals Th...

Page 29: ...ut into your Startup Windows program folder Double clicking on the exe file will allow the Remote Dashboard to find the iLC2ST on the network and automatically configure the IP Address needed to estab...

Page 30: ...the window there are three navigation tabs Stereo A Stereo B and Settings Click on the Settings tab in order to configure the program After initial configuration the application will start and resume...

Page 31: ...econds the application will poll iLC2ST for its readings Data Logging Specifies the location for storing log files This path may be local or on a network share that the active Windows user has permiss...

Page 32: ...ode table Data logging Field Legend Error Codes After the appropriate options have been set press the APPLY button to save those settings and begin communications with the iLCST The program icon shoul...

Page 33: ...ight click on the tray icon and select EXIT 2 Navigation Tabs Clicking on the tab will change the current view of the program between Surround inputs Stereo inputs or the Remote Dashboard configuratio...

Page 34: ...folder A full day of logging each available data field once per second will consume approximately 27MB of storage space Storage of files onto flash drives or other solid state storage devices is not r...

Page 35: ...file click the first value hold the shift key and then click on the last value 7 In Excel 2007 click on the Insert tab Click the Line button and then select Line under the 2 D Line group In Excel 200...

Page 36: ...ned above a sample radar style graph was created This graph type can be found in Excel 2007 by clicking on the Other Charts button and then selecting Radar or in Excel 2000 2003 by selecting Radar fro...

Page 37: ...erra 1 Un Zip the files using a compatible utility that can handle ZIP archive file format into a new empty directory on your PC 2 Disable any additional network interface adapters present on your PC...

Page 38: ...Enter the time server address to be used or use the public pool time nist gov 4 Press APPLY then UPDATE now to ensure the server address can be contacted A message will appear below the server addres...

Page 39: ...scope 2 Is there a software firewall running blocking access to the UDP port 44600 Make sure the port is open or the Remote Dashboard software is in your firewall s exclusion or white list Contact yo...

Page 40: ...customer accordingly DaySequerra reserves the right to replace any product that has been discontinued from its product line with a new product of comparable value and function This warranty shall be...

Page 41: ...er Manual 41 Manufactured under license from DTS Licensing Limited DTS and the Symbol are registered trademarks and the DTS logo is a trademark of DTS Inc Product includes software DTS Inc All Rights...

Reviews: