DAYLIFF MJ Installation And Operation Manual Download Page 8

4

6

Fig 2

Ÿ

After  installation  is  complete  and  prior  to  opening  the  upstream/inlet 
water valve ensure that the valve on the downstream/outlet side of the 
meter is shut. 

Ÿ

In  case  the  main/service  shut-off  valve  is  closed,  open  it  slowly  to 
pressurize the service line to the meter setting. Air in the lines may damage 
a meter and other equipment. Water hammer from a quick turn-on can 
damage plumbing and appliances or cause a water line rupture. 

Ÿ

Slowly open the inlet side valve which will fill the meter with water. Once 
the water is flowing fully open the meter inlet valve . Partially open valves 
can render the meter inaccurate and lead to low water pressure. 

Ÿ

Check  for  leaks  around  the  meter  and  connections.  Open  a 
downstream/consumer faucet to allow entrapped air to escape once the 
outlet  valve  is  opened.  Open  the  meter  outlet  side  valve  slowly  to 
pressurize  the  downstream/  consumer  side  of  the  system.  Turn  off  the 
consumer faucet when normal water flow occurs. 

Ÿ

Ensuring that all consumer faucets are shut, observe the low flow detector 
in the meter to identify downstream leaks in the consumer's system. 

WP Installation

Ÿ

The meter must be installed with the direction of the flow as indicated by 
the arrow cast  in the meter body.

Ÿ

In order to keep the water meter in good working condition, the pipeline 
should be cleared before installation.

Ÿ

A horizontal position with the register face upwards is recommended.

Ÿ

The meter must have 10 diameters straight pipe ahead of the meter and 5 
diameters straight pipe after to ensure proper flow through the meter.

Ÿ

The valves must be installed in the front and the back of the water meter.

Ÿ

Attention should be paid that a cold water meter must not be used for hot 
water..

Ÿ

 It is recommended to install a filter before water meter.

WARNING

The meter can be damaged if subjected to full ow 
conditions  prior  to  expelling  all  the  air  from  the 
pipeline

Summary of Contents for MJ

Page 1: ...WATER METERS Installation Operating Manual MJ PD WP...

Page 2: ...SPECIFICATIONS 1 1 2 SYMBOLS WARNINGS 3 INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted 3 INSTALLATION 4 4 OPERATION MAINTENANCE 7 5 TERMS OF WARRANTY 9...

Page 3: ...r DN15 and DN20 sizes and brass for larger sizes Meters are supplied with inlet strainers and union connectors PD Rotary piston type meters that provide high accuracy over a wide flow range The mechan...

Page 4: ...9999 999999 40 0 2 1 15 1 5 3 15 10 40 0 2 1 20 2 5 6 10 3 5 5 12 20 7 50 120 200 70 16 16 16 16 40 40 40 40 0 25 0 24 0 2 0 25 1 1 0 9 1 1 20 2 5 5 25 16 40 0 25 1 50 15 30 7 5 16 50 2 0 02 0 08 65 2...

Page 5: ...lic CAUTION Instructions should be carried out by a qualified professional with parts equipment approved by the local codes and regulations WARNING Meter must not be used as a lever or crowbar to stra...

Page 6: ...otective packaging to the point of installation Storage temperatures shall remain within the range of 20 C to 60 C avoiding direct sunlight Special fittings and accessories are available to provide ea...

Page 7: ...e properly aligned to avoid cross threading damage stripping to the meter ends This is especially important for the engineered composite polymer meter The best method for properly starting meter coupl...

Page 8: ...lowly to pressurize the downstream consumer side of the system Turn off the consumer faucet when normal water flow occurs Ensuring that all consumer faucets are shut observe the low flow detector in t...

Page 9: ...ance as shown in Fig 2 Volumetric meters may also be installed vertically or at an incline Ensure that the installed meter will be easily accessible for reading inspection and service Protect the mete...

Page 10: ...16 bar If there is a pressure regulator verify that the regulator works and is adjusted correctly The service pipe entering and exiting the meter box should be properly bedded to ensure that it is no...

Page 11: ...bility In lieu of any warranty condition or liability implied by law the liability of Dayliff in respect of any defect or failure of equipment supplied is limited to making good by replacement or repa...

Page 12: ...INS450A 02 20 www davisandshirtliff com...

Reviews: