4. OPERATION
Priming the pump
To start the pump, it is necessary to prime it by filling with water. Do not start the
pump until it has been filled with water.
Ÿ
Unscrew the priming plug and allow an even flow of water.
Ÿ
Screw the plug on again. The pump is now ready to start.
Starting the pump with control panel
Ÿ
To prepare the pump for venting, open a tap.
Ÿ
Insert the power plug into the socket and turn on the power supply. The pump will
power after 3 seconds after main power is introduced.
Ÿ
Close the tap once water flows.
Ÿ
Open the highest tap point in the installation, such as a shower.
Ÿ
Use the buttons to adjust the pressure set point to the required pressure.
Ÿ
Once done, close the tap.
To set pressure
Ÿ
The pump's water pressure can be adjusted to any value between 1.5 to 6.0 bar
and 7 bar for DSmart 1500.
Ÿ
The default pressure, as indicated is 2 bar which for most applications is sufficient.
The difference between inlet pressure and outlet pressure must not exceed 3.5
bar. For example, if the inlet pressure is 0.5 bar, the maximum outlet pressure
should be 4 bar.
Outlet
Priming Plug
Inlet
Drain Plug