48
Drying your room
Press MODE button on the control panel or
remote control, the LED of DRY operation
lights up. The fan speed is unable to select.
User should connect the hose to the drain
outlet at the bottom of the appliance.
Note: In this mode, the fan speed switches
over to low speed andthe temperature
cannot be selected.
Sleep mode
This function can only be used with a remote
control.
The sleep mode can be activated when in
cool mode.
After 1 hour the preset temperature is
increased by 1 °C, after another hour the
preset temperature will again be increased
by 1 °C.
Timer setting (1-24 hours)
The timer has two ways of operation.
To turn off (when power on):
Press Timer key to turn on the timer function.
Press ADD/MINUS repeatedly to set the delay
OFF time.
To turn on (when power off):
Press Timer key to turn on the timer function.
Press ADD/MINUS repeatedly to set the delay
ON time.
Cancel timer
Press ADD/MINUS repeatedly until the LED
shows ‘00’.
Note: when press POWER will also exit the
timer setting.
Automatic Defrost
At low room temperatures, frost may buildup
at the evaporator during operation. The
appliance will automatically start defrosting
and the POWER LED blinking. The defrost
control sequence is as follows:
When the appliance operates in the cooling
operation, drying operation, the ambient
temperature sensor senses the evaporator
coil temperature is below -1°C, after the
compressor will stop operating for 10
minutes or the coil temperature up to 7 °C,
the appliance restart to cool operating mode.
When the appliance operates in the drying
operation, once the coil temperature
sensor senses the temperature of the
evaporator is below 40 °C and the differential
temperature between coil temperature and
room temperature is below 19 °C after the
compressor operation for 20minutes, the
appliance start defrosting for 5 minutes and
the power indicator blinking.
Overload Protection
In the event of a power loss, to protect the
compressor there is a 3-minute delay until
the compressor restarting.