  Check  pipes  and  connections  pipes  regularly.  If  you  suspect  that  there  is  gas 

leakage caused by pipe and connection pipes, consult to number 187 gas failure 

department of necessary gas company.  

  If you suspect that there is gas leakage except pipe and pipe connections consult 

to your service agency.   

  Make urgently change old or cracked pipes by authorized person   after controlling 

gas pipes regularly. 

  When unusual burning sound is heard in water, stop using the water heater and 

consult to our service agency. 

  Please check water flow temperature with your hand before applying your body 

in case of burning.  

 

 

  Check the newly mounted water heater carefully and make sure that it operates 

properly before using. 

  Do not drink the water passing inside the water heater 

  Take precautions for not blocking of heat exchanger because of specification of 

water such as (hard water). Blocking of water heater exchanger is out of warranty.  

   If  your  pressure of  installation  is high,  because  of  water  quantity  passing  from 

water heater will be more, noise can occur at device and your installation can be 

damage. In such cases, absolutely you need to install pressure reduce valve to 

device inlet.   

  If  necessary  precautions  are  not  taken,  situations  which  ambient  temperature 

deduct under the 0 degree, water inside heater can give damage to your heater 

by freezing. It is possible to prevent this situation by doing following information.  

   With freezing prevention of your water even device inside temperature reduce 

under “0” degree, it can be prevented freezing of water which is inside the 

device.  When  ambient  temperature  decreases  specific  value,  your  water 

heater  will  heat  water  by  automatically  operating  in  short  period  and  will 

prevent freezing. In the meantime, 

“AF” warning will be seen.  

6.4. For The Safe Use 

 

Summary of Contents for UKDAX-11ST

Page 1: ...1...

Page 2: ...evice by yourself In case of you use LPG gas do not mount your water heater in places below the ground level Check whether your device conforms to the gas type you will use or not Provide flexible con...

Page 3: ...ty is prevented and the water is cooled after the flame is off with the features of blowing inside the water heater before the ignition air fan blows air for 2 4 seconds before ignition and the blowin...

Page 4: ...4 instant water flow instant gas consumption and warnings In case of fault condition it gives information about fault reason with fault code 3 THE CONFIGURATION OF WATER HEATER...

Page 5: ...in 0 3 Bar Max 10 Bar Minimum Water Flow 2 7 l dak Electrical Power 34 W Electrical Connection 220 V 50 Hz AC Protection Class IP 44 Net Weight 9 4 kg Dimensions 522 x335 x 145 Connections Cold Water...

Page 6: ...use device out of function The environment where the water heater is mounted should be free from blocking preventing parts and projections during the repair and maintenance there should be sufficient...

Page 7: ...ix the appropriate diameter fixing plug to the holes Drill 110 mm diameter waste gas pipe hole according to pipe dimensions given in the figure below Waste gas pipes are provided with water heater All...

Page 8: ...alling one edge is to heater pipe another edge is to discharge pipe Fill the hole on the wall opened for discharge pipe with fire resistance material and insulate it Make sure that insulation is done...

Page 9: ...lity entering dirt from water network to inside of heater With flexible pipe connect cold water inlet of device to cold water supply network hot water outlet to hot water supply network Seal must be u...

Page 10: ...nd by decreasing with button Turn On water tap At the display of the heater it is respectively seen water flow sign fan operation sign and in a few min water heating start sign and your water heater s...

Page 11: ...hen it is pressed twice numerical values between 00 and 99 are appeared With or buttons intended flow rate between 10 and 99 is set When total flow rate passes from heater reaches to set value warns w...

Page 12: ...nt The repair of the water heater as unauthorized is dangerous and it may cause accidents Unauthorized repairing or have repaired device to unauthorized person is dangerous and may cause to accidents...

Page 13: ...ing of heat exchanger because of specification of water such as hard water Blocking of water heater exchanger is out of warranty If your pressure of installation is high because of water quantity pass...

Page 14: ...echnician Dirty water passing inside the water heater may negatively affect your device To prevent this a water filter must be absolutely installed to water inlet Never leave electric supply and gas o...

Page 15: ...ce or not Change gas type or open gas valve Call Authorized Service E4 Fan Operation Failure Fan Connection Failure Main Control Board Failure Call Authorized Service E5 Water Outlet Temperature is po...

Page 16: ...all authorized service Water valve is not turn on enough Turn On water valve completely Insufficient fresh air Control device pipe Windy weather Do not use it until the wind passes Freezing water Use...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Page 21: ...ted irketi Nam k Kemal Mah Marmara Cad No 74 mraniye stanbul Tel 90 216 369 85 36 37 Fax 90 216 385 95 45 E Mail info daxom com Merkez Servis Nam k Kemal Mah Marmara Cad No 74 mraniye stanbul Tel 90 2...

Page 22: ...22...

Reviews: