Fresh air and exhaust gas length must be calculated according to following table.
Total equivalent pipe length (ΣL
eq
) must be equal or smaller than maximum equivalent
pipe length (L
max
)
TABLE-1
80/125
80+80
100/150
100+100
C13
5
5+5
8
8+8
C33
5
5+5
8
8+8
C53
5+5
8+8
C13
5
5+5
8
8+8
C33
5
5+5
8
8+8
C53
5+5
8+8
C13
5
5+5
8
8+8
C33
5
5+5
8
8+8
C53
5+5
8+8
MAXIMUM EQUIVALENT PIPE LENGTH TABLE (L
max
)
MODEL
PIPE TYPE
MAXIMUM EQUIVALENT PIPE LENGTH (m)
UKDAX-***GB25
UKDAX-***GB65
UKDAX-***GB35
TABLE-2A
80/125
80+80
100/150
100+100
90
o
BEND
1
1
1
1
45
o
BEND
0,5
0,5
0,5
0,5
UKDAX-***GB25 EQUIVALENT LENGTH CALCULATION TABLE (L
eq
)
PIPE
CONNECTION
PART
EQUIVALENT PIPE LENGTH (m)
TABLE-2B
80/125
80+80
100/150
100+100
90
o
BEND
1
1
1
1
45
o
BEND
0,5
0,5
0,5
0,5
UKDAX-***GB35 EQUIVALENT LENGTH CALCULATION TABLE (L
eq
)
PIPE
CONNECTION
PART
EQUIVALENT PIPE LENGTH (m)
TABLE-2C
80/125
80+80
100/150
100+100
90
o
BEND
1
1
1
1
45
o
BEND
0,5
0,5
0,5
0,5
UKDAX-***GB65 EQUIVALENT LENGTH CALCULATION TABLE(L
eq
)
PIPE
CONNECTION
PART
EQUIVALENT PIPE LENGTH (m)
4.3.1. Fresh Air and Exhaust Gas Pipe Installation Length