connected to close drain. Siphon must be installed to condensing outlet together with
product. Drainage connection mıust be with pipe durable to condensing water.
(preferably PVC)
After installment connections are completed, boiler is needed to fill. This process
must be done by implementing following instructions.
Open water inlet valve of product.
Turn on any tap connected to hot water outlet of product (preferably nearest tap).
Air inside the boiler will be discharged from water faucet.
Turn off tap after air is discharged from tap and continious water flow.
After boiler is filled, it must be controlled studiouslyif there is water leakage or
not.
Electric installation must be done by enough knowledge person.
For the electric supply of product, automatic fuse with suitable amper value must be
near to product and easily accessible. Fuse connection of product cables must be
done by authorised service.