23
6.4.5. Room Thermostad Connection
It is possible to command device with room thermostad. In this way, device
operates according to temperature of environment of room thermostad place. Room
thermostad temperature must be done by authorized service while first operation of
device is making.
6.4.6. HEATING MODE SETTING
Device can be set according to floor heating (low temperature) or radiator heating
system. In this way, overheating is prevented especially for floor heating systems.
While the device is operating at floor heating mode max 55 degrees, it can be set
max 80 C at radiator heating mode. Devices connected to floor heating systems will
be taken to floor heating mode by authorized services at the time of first operation.
In this way, in this case, it will be impossible to change heating mode for users by
consciously or by mistake. For radiator heating modes, is users want, they can
provide operation of device max 55C by changing into heating mode to ground
heating mode. While
symbol is seen at radiator mode , it is not seen at floor
heating mode.
While device is operating regulary
Enter the setting menu by pressing
2-3 seconds
Press
button one second interval until
is seen. Heating mode choosing
indicator blinks.