Fault Code
Fault
Solution
E0
➢
Insufficient water pressure
➢
Adjust the water pressure between 1-2 bar
➢
Water pressure switch
malfunction
➢
Call the authorized service
E1
➢
Heater sensor malfunction
➢
If you continue to receive the same fault
code after waiting for a while, call the
authorized service.
E3
➢
Water temperature above
85°C warning
➢
After a few minutes, the device will start to
operate.
E4
➢
Will start to work when the temperature
drops below 85°C
➢
Limit thermostat will start to
work warning
➢
If the same fault code continues to appear
despite waiting for a while, call the
authorized service.
E5
➢
Pipe clogged or valve
closed
➢
Check if there is a shut valve in the heating
installation and no pump failure and clean
the silt trap
➢
Pump malfunction
➢
Flow meter malfunction
➢
Call the authorized service
8. REPAIR AND SERVICE