During guarantee time we provide Free of Charge Service to our
customers against defect of related materials and production. When you
meet with problem while using, please contact with our after sales
service department. Repairing and maintenance of the device by
unauthorizedperson will make the device out of warranty. Afterwards our
company will not responsible from damages and accidents.
Damage Code
Damage
Solution
E0
1- Water pressure is not enough
2- Water pressure switch damage
1- Set the water pressure between 1-2 bars.
2- Call authorized service
E1
Heating sensor damage
Although you wait for a while, if you have still seen the
same code, call the authorized service.
E3
Warning of water temperature is over 85
o
C
1 min later device will start to operate.
E4
Warning of limit thermostat is in circuit
1- When the temperature is down under 85
o
C, it is
going to start operate.
2- Although you wait for a while, if you have still seen
the same code, call the authorized service.
E5
1-Pipe is blocked or valve is closed 2-Pump
damage
3-Flowmeter damage
1- Control if it is closed valve or not at heating
installation and clean silt trap.
2- Call the authorized service
8. MAINTENANCE AND SERVICE