For short time absence periods, provide the device OFF by pressing
button 2 or 3 seconds. In this way, (by activating electric and fuel supply)
device will be protected by following steps.
Freezing Prevention Function: If temperature of water inside device reduces
under 5
O
C, pump and heating will operate for bringing the water temperature
to security level (35
O
C).
During Anti –frost cycle
is seen at LCD.
Anti – Blockade Function: Pump and 3 way valve inside the device start to
operate once every 18 hrs.
If you do not operate the device for a long time, make the circuit breaker
OFF after pressing button 2or 3 seconds. In this case, because of
freezing prevention of the device will not operate discharge the water
inside device in case of freezing risk.
6.6 MAKING DEVICE OFF
6.6.1 TEMPORARILY OFF
6.6.2 LONG PERIOD OFF