background image


 

Maintenance and Repair 

Repair 

Please follow these steps closely if the Meter is not 
functioning properly: 

 

 

Follow User Manual to confirm every procedure. 

 

Before sending Meter back for repair, include a 
description of the problems encountered. Remove 
batteries and pack Meter well to avoid damage in 
delivery, Dawson does not cover damage due to 
delivery.   

 

Repair or service not covered in this manual should 
be performed only by the authorized service center 
or qualified personnel. 

 

Replacing Batteries 

Follow these steps to replace batteries: 
 

 

Loosen and remove the battery cap at the back of 
the meter pen. 

 

Remove the batteries and replace the batteries 
with new batteries. 

 

Reattach the battery cap to the meter. 

 

Summary of Contents for DET 161

Page 1: ...Dawson DET 161 AC Voltage Detector User s Manual...

Page 2: ...the Box 2 Accessories 3 Important Safety Information 5 Certification 5 INTRODUCTION 5 Overview 5 USING THE METER 7 AC Voltage Measurement 7 SPECIFICATIONS 8 General Specification 8 MAINTENANCE AND RE...

Page 3: ...ice center at 800 898 6991 or visit www DawsonTools com to obtain a return authorization within the US only A return authorization is necessary before returning any instrument to Dawson no service wil...

Page 4: ...ED IN THE USER MANUAL READ THE USER MANUALS BEFORE USING THE METER Avoid shaking dropping or any kind of impacts when using or transporting the Meter To avoid electric shock or personal injury repairs...

Page 5: ...ec Avoid exposing batteries to humidity Replace batteries as soon as the low battery indicator appears Please keep the original packing for future shipping purposes ex Calibration After opening the bo...

Page 6: ...lemented by trained personnel Certification CAT III This meter has meet IEC1010 1 standard with an overvoltage category CAT III and pollution2 The Meter is compiled to EMC requirements Introduction Ov...

Page 7: ...HIGH VOLTAGE CIRCUITS TO AVOID ELECTRICAL SHOCK AND INJURY DO NOT TEST VOLTAGES HIGHER THAN DC AC 600V Insert the probe tip into the hot prong shorter slot of outlet or into the desired target If AC...

Page 8: ...I 600V Frequency range 50 60Hz Measuring distance 5mm Power Supply 1 5V 2 AAA battery Humidity 85 relative humidity Operating Temperature 32 F To 122 F 0 to 50 Storage Temperature 4 F To 140 F 20 to 6...

Page 9: ...eries and pack Meter well to avoid damage in delivery Dawson does not cover damage due to delivery Repair or service not covered in this manual should be performed only by the authorized service cente...

Page 10: ...9 Contact Dawson Dawson Tools Inc 1142 S Diamond Bar Blvd 858 Diamond Bar CA 91765 Phone 310 728 6220 www DawsonTools com Do not recycle Back Page Features Auto Power Off...