The measured values at the lower surface of the tailing edge, all depth and spacing of the articulation points were
determined under tensile load of 50N.
The length difference is not more than
±
10 mm
Canopy measurement
XS
Position
Rib # from center Distance [mm] Tension [daN] Manual tolerances
Aspect ratio
4*span / (chord A+2.5*Chord B)
Full Span
x
12090
5
+/-2%
7.63
1/2 Trailing Edge
x
6150
5
+/-1%
Chord A
1
1972
1
+/-1%
Chord B
29
1745
1
+/-1%
On first lined rib
(from center)
Rib n
°
from center
Distance [mm]
Tension [daN]
Manual
tolerances
Chord
5
1972
1
+/-1%
Top of inlet
5
1898
5
+/-1%
Bottom of inlet
5
1862
5
+/-1%
Tab Aa*
5
1720
5
+/-10mm
Tab Ab*
5
1590
5
+/-10mm
Tab B*
5
900
5
+/-10mm
Tab C*
5
628
5
+/-10mm
On last lined rib of Group 2 (from center) Rib n
°
from center
Distance [mm]
Tension [daN]
Manual
tolerances
Chord
24
1834
1
+/-1%
Top of inlet
24
1774
5
+/-1%
Bottom of inlet
24
1740
5
+/-1%
Tab Aa*
24
1580
5
+/-10mm
Tab Ab*
24
1475
5
+/-10mm
Tab B*
24
835
5
+/-10mm
Tab C*
+/-10mm
On last lined rib (stabilo, from center)
Rib n
°
from center
Distance [mm]
Tension [daN]
Manual
tolerances
Chord
64
445
1
+/-1%
Tab A*
64
375
5
+/-10mm
Tab B*
64
207
5
+/-10mm
S
Position
Rib # from center Distance [mm] Tension [daN] Manual tolerances
Aspect ratio
4*span / (chord A+2.5*Chord B)
Full Span
x
12600
5
+/-2%
7.60
1/2 Trailing Edge
x
6290
5
+/-1%
Chord A
1
2069
1
+/-1%
Chord B
29
1825
1
+/-1%
On first lined rib
(from center)
Rib n
°
from center
Distance [mm]
Tension [daN]
Manual
tolerances
Chord
5
2057
1
+/-1%
Top of inlet
5
1983
5
+/-1%
Bottom of inlet
5
1947
5
+/-1%
Tab Aa*
5
1767
5
+/-10mm
Tab Ab*
5
1644
5
+/-10mm
Tab B*
5
932
5
+/-10mm
Tab C*
5
657
5
+/-10mm
On last lined rib of Group 2 (from center) Rib n
°
from center
Distance [mm]
Tension [daN]
Manual
tolerances
Chord
24
1908
1
+/-1%
Top of inlet
24
1845
5
+/-1%
Bottom of inlet
24
1811
5
+/-1%
Tab Aa*
24
1644
5
+/-10mm
Tab Ab*
24
1532
5
+/-10mm
Tab B*
24
866
5
+/-10mm
Tab C*
+/-10mm
On last lined rib (stabilo, from center)
Rib n
°
from center
Distance [mm]
Tension [daN]
Manual
tolerances
Chord
64
465
1
+/-1%
Tab A*
64
389
5
+/-10mm
Tab B*
64
215
5
+/-10mm