1.0 GENERAL
The DV-11T is a thermostatically controlled
ventilation control system for an EXHAUSTER
or BLOWER, with minimum and maximum
regulation.
1.1 TECHNICAL DATA
Dimensions
110 x 210 x 70mm.
Required voltage
: 230 Vac / 50Hz.
Max. Output
: 6 Amperes.
Isolation level
: IP-44
1.2 REQUIRED (ACTIVE) VOLTAGE DV-11T
To connect the DV-11T you will preferably need
a ‘clean’ group of at least 6 Amp. A ‘clean’ group
means that this group will only be used by the
DV-11T.
• The DV-11T needs to be connected directly to,
and near the ‘clean’ group.
• Install, if needed, a grounded outlet onto your
‘clean’ group.
• If you do not have a(n) (extra) ‘clean’ group we
advise you to have a ‘clean’ group installed by
a certified installer.
1.3 THE INSTALLATION OF THE DV-11T
The DV-11T should now be mounted.
At the bottom of the DV-11T are 2 mounting
brackets; these should be pushed out before
you can use them. The DV-11T can now easily be
placed on a (flat) surface.
1.4 CONNECTING THE DV-11T TO A ‘CLEAN’
GROUP
• In step 1.2 you have already mounted a
grounded outlet onto your ‘clean’ group.
• Turn the ‘clean’ group ‘OFF’.
• Insert the plug of the DV-11T into the outlet of
the ‘clean’ group.
1.5 CONNECTING THE ENGINE (EXHAUSTER)
TO THE DV-11T
In steps 1.2 to 1.4;
• A ‘clean’ group is connected (or we have had it
connected by a certified installer.)
• The DV-11T has been mounted onto a flat
surface.
• The DV-11T has been connected to a ‘clean’
group.
Now the engine (of the exhauster) needs to be
connected to the DV-11T.
• Insert the plug of the exhauster into the
mounting socket (the socket) on the side of
the DV-11T.
• Turn the ‘clean’ group back ‘ON’
• If everything is properly connected, the engine
of the exhauster will start.
1.6 ADJUSTING THE DV-11T
Everything is now connected. Now the DV-11T
can be adjusted for use.
On top of the DV-11T there are three black
buttons.
• Button 1 = Thermostat
Adjust this to the desired temperature.
• Button 2 = Minimum speed regulation
Adjust this to the desired maximum speed.
• Button 3 = Maximum speed regulation
Adjust this to the desired minimum speed.
HU