11
Manual
DV‑101A
NON-STANDARD
For example, if you wish to water every 1 minute and 30 seconds, this is not possible via the standard
settings. To program a ‘Non-standard’ time setting on the DV-101A you can consult the tables below.
‘DIP-switch’ 4 is ALWAYS on:
SwITch SETTING
DIP-switch
setting
Max.
time
0
10
20
30
40
50
60
15 sec. 0 sec.
2½ sec.
5 sec.
7½ sec.
10 sec.
12½ sec.
15 sec.
60 sec. 0 sec.
10 sec.
20 sec.
30 sec.
40 sec.
50 sec.
60 sec.
7.5 min. 0 sec.
75 sec.
1:15 min.
150 sec.
2:30 min.
225 sec.
3:45 min.
300 sec.
5 min.
375 sec.
6:15 min.
450 sec.
7:30 min
60 min. 0 sec.
10 min.
20 min.
30 min.
40 min.
50 min.
60 min.
To water every 1 minute and 30 seconds:
• The ‘DIP-switch’ setting has to be put on 7,5 min.
• And the switch has to be turned to ± 12.
• Almost every possible setting can be found in the table above, almost always via the ‘DIP-switch’
setting 7,5 min.
ScALE MARKING
MAx. NuMbER Of
SEcOND
EvERy STRIPE ON ThE
cLOcK =
DIP-SwITch MODE
15 sec
15
0.25 sec.
60 sec
60
1 sec.
7,5 min.
450
7.5 sec.
60 min.
3600
60 sec.
(Normally the 60 min. setting is never used for our purposes, when in doubt please call the helpdesk.)