![Davies Craig DCSL-8 Installation Instructions Manual Download Page 6](http://html1.mh-extra.com/html/davies-craig/dcsl-8/dcsl-8_installation-instructions-manual_514575006.webp)
P/No:0950
6
DAVIES, CRAIG THERMATIC FAN WIRING DIAGRAMS WITH #0401 SWITCH
1
ONE FAN, CONDENSER ONLY
1
BLUE CONNECTOR
(FROM FAN KIT)
2
SELF TAPPER
(FROM FAN KIT)
3
SCOTCHLOCK
(FROM FAN KIT)
4
RING TERMINAL
(FROM FAN KIT)
5
FUSE HOLDER & FUSE
(FROM FAN KIT LOOM)
PURCHASE: 1 FAN KIT
2
ONE FAN, THERMATIC ONLY
1
BLUE CONNECTOR
(FROM FAN KIT)
2
SELF TAPPERN
(FROM FAN KIT)
3
SCOTCHLOCK
(FROM FAN KIT)
4
RING TERMINAL
(FROM FAN KIT)
5
FUSE HOLDER & FUSE
(FROM FAN KIT LOOM)
6
FEMALE SPADE BLUE
(FROM THERMAL SWITCH KIT)
7
FEMALE SPADE BLUE
(FROM THERMAL SWITCH KIT)
8
COILED BLUE WIRE
(FROM THERMAL SWITCH KIT)
PURCHASE: 1 FAN KIT, 1 THERMAL SWITCH
KIT P/NO: 0401
3
ONE FAN, CONDENSER
AND / OR THERMATIC
1
BLUE CONNECTOR
(FROM FAN KIT)
2
SELF TAPPER
(FROM FAN & THERMAL SWITCH KIT)
3
SCOTCHLOCK
(FROM FAN & THERMAL SWITCH KIT)
4
RING TERMINAL
(FROM FAN KIT)
5
FUSE HOLDER & FUSE
(FROM FAN KIT LOOM)
6
FEMALE SPADE BLUE
(FROM THERMAL SWITCH KIT)
7
FEMALE SPADE BLUE
(FROM THERMAL SWITCH KIT)
8
COILED BLUE WIRE
(FROM THERMAL SWITCH KIT)
PURCHASE: 1 FAN KIT, 1 THERMAL SWITCH
& RELAY KIT P/NO: 0404
4
TWIN FANS, THERMATIC ONLY
1
BLUE CONNECTOR
(FROM FAN KITS)
2
SELF TAPPER
(FROM FAN KITS)
3
SCOTCHLOCK
(FROM FAN KITS)
4
RING TERMINAL
(FROM FAN KITS)
5
FUSE HOLDER & FUSE
(FROM FAN KITS)
6
FEMALE SPADE BLUE
(FROM THERMAL SWITCH KIT)
7
FEMALE SPADE BLUE
(FROM THERMAL SWITCH KIT)
8
COILED BLUE WIRE
(FROM THERMAL SWITCH KIT)
PURCHASE: 1 FAN KIT, 1 THERMAL SWITCH
KIT P/NO: 0401
5
TWIN FAN, THERMATIC
SINGLE FAN CONDENSER
1
BLUE CONNECTOR
(FROM FAN KITS)
2
SELF TAPPER
(FROM FAN & THERMAL SWITCH KIT)
3
SCOTCHLOCK
(FROM FAN KITS)
4
RING TERMINAL
(FROM FAN KITS)
5
FUSE HOLDER & FUSE
(FROM FAN KITS)
6
FEMALE SPADE BLUE
(FROM THERMAL SWITCH KIT)
7
FEMALE SPADE BLUE
(FROM THERMAL SWITCH KIT)
8
COILED BLUE WIRE
(FROM THERMAL SWITCH KIT)
PURCHASE: 2 FAN KITS, 1 THERMAL SWITCH
& RELAY KIT P/NO: 0404
6
TWIN FANS, CONDENSER ONLY
1
BLUE CONNECTOR
(FROM FAN KIT)
2
SELF TAPPER
(FROM FAN KITS)
3
SCOTCHLOCK
(FROM FAN KITS)
4
RING TERMINAL
(FROM FAN KITS)
5
FUSE HOLDER & FUSE
(FROM FAN KITS)
PURCHASE: 2 FAN KITS
Note: Colour of motor leads depends on fan location (upstream/downstream)
If in doubt, refer to the rotation and polarity chart.
The two terminals on the thermal switch are equivalent. It does not matter which goes to the ignition and which
WARNING:
ENSURE IGNITION SOURCE IS NOT CONNECTED TO THE ENGINE MANAGEMENT SYSTEM
WARNING:
ENSURE IGNITION SOURCE IS NOT CONNECTED TO THE ENGINE MANAGEMENT SYSTEM
WARNING:
ENSURE IGNITION SOURCE IS NOT CONNECTED TO THE ENGINE MANAGEMENT SYSTEM
WARNING:
ENSURE IGNITION SOURCE IS NOT CONNECTED TO THE ENGINE MANAGEMENT SYSTEM