GD-04 DAVID 

 

MKS51200_OS1 

12

Relays X and Y operation 

SMS to switch relay ON 

ARX, xxx..x 

Use 

ARY 

for relay 

Y

.

 xxx..x

 = text (up to 30 

characters), text erased by 

ARX, ,

  

Example: 

ARY,ventilator on

  

erased 

SMS to switch relay OFF 

DRX, xxx..x 

Use 

DRY 

for relay 

Y

.

 

xxx..x

 = text (up to 30 

characters), text erased by 

DRX, ,

  

Example: 

DRY,ventilator off

  

erased 

Relay switch-on period 

TMX, t..t 

Use 

TMY 

for relay 

Y

.

  

t..t

 = switch-on period in seconds, or zero 

 1 to 36000 (10h): the relay works as a time-

switch, activated via switch-on SMSes or 

dialling-in, deactivated by time-limit expiration 

or via switch-off SMSes. 

  0: no time-limit applies, dialling-in is responded 

to with toggle logic: on – off – on… 

 

0  

(no limit) 

Telephone numbers 
authorised for relay control 

ADX, x..x,x..x  

Use 

ADY 

for relay 

Y

.

  

x..x

 = tel. number. Up to 50 numbers can be entered 

(in a single instruction or gradually).  The numbers are 
added to the list of authorised numbers. Example: 

ADX, 777123456, +420608503211

 authorises two 

new numbers for relay X control.

 

Telephone numbers 
authorised for relay control 
with a validity limit. 

LDX, x..x,n, 

x..x,n  

Use 

LDY

 for relay 

Y

.

 

 

x..x

 = tel. number. The numbers are added to the list of 

authorised numbers, up to 50 in total. 

= limit in the number of calls (1 to 99), exceeding the 

limit removes the number from the list – this is reported 
to the service number by SMS. 
Example: 

LDX, 777123457, 31

 authorises a new 

number for relay X control for a maximum of 31 calls.

 

empty 

list 

 

Erasing tel. numbers 
authorised for relay control 

EDX, x..x, x..x 

Use 

EDY 

for relay 

Y

.

  x..x

 = tel. number.  The 

numbers (up to 50) are removed from the list. 
Example:

 EDX, 777123457

 de-authorises a single 

tel. number used for relay X control. 

– 

Input A to D activation/deactivation SMS reports 

Input activation text  

ATA, xx..x 

Use

 ATB 

for input 

B

, etc. 

xxx..x 

= text (up to 30 characters*)  

Example: 

ATC, heating on

  

Instruction 

ATA , ,

 erases the text = no reports  

A1,  
B1,  
C1,  

D1 

Input deactivation text  

DTA, xx..x 

Use

 DTB 

for input 

B

, etc. 

xxx..x 

= text (up to 30 characters*)  

Example: D

TC, heating off

 

Instruction 

DTA , ,

 erases the text = no reports 

A0,  
B0,  
C0,  

D0 

Telephone numbers for 
input reports 

TNA, x..x, x..x 

Use 

TNB

 for input 

B

, etc. 

x..x

 = tel. number, up to 8 for each input. All 

previously stored numbers are erased. Use 

TNA,

 

to empty the list. 
Example: 

TND, 777123456, 608123456  

sets 

David to report input D events to 2 numbers 

empty  

list 

Input-event calls 

DNA, n 

Use 

TNB

 for input 

B

, etc.

n

 = 1 (ON), 0 (OFF). If 

set to ON, every SMS report is followed by a call. 
If you answer the call, you hear a constant tone = 
activation, or an interrupted tone = deactivation. 
Example: 

DND, 1

  

OFF 

Summary of Contents for GD-04

Page 1: ......

Page 2: ......

Page 3: ...k We hope that the skills of your tiny David will help you manage the giant 1 Basic description SIM Bus connector Battery connection LED indicator RESET jumper GSM antenna Tabs SIM card Output fuses 1 1 David provides 2 output contacts of power relays X and Y each allows up to 5A 250V 4 input terminals A to D for SMS reporting the inputs react to a connection or disconnection to or from a common G...

Page 4: ...D 04P link cable which allows you to connect David to a PC through a USB port and perform any desired configuration using GDLink software A GD 04R radio module which allows input A to D activations via wireless buttons or detectors of the OASiS series and also provides David with the capability of output relay X or Y state transmission to UC or AC OASiS receivers In addition you can control relays...

Page 5: ...upply can be connected to these terminals they can only be controlled via a potential free switch contact Example of wiring a switch to input A Switch 5 Initial powering up 1 Turn the power supply on registering to the GSM network is indicated by the LED flashing if no indication occurs check the power supply wiring 2 After GSM registration the LED stops flashing usually within 1 minute Continued ...

Page 6: ... a USB port the cable is supplied separately GDLink software is available either in the GD 04P s package or on the www jablotron cz web site David s communication protocol is available for use by other computer programs which can thus utilize GD 04 transfers including programming instructions or GSM status information 6 3 SMS instructions David can also be configured via SMS instructions from your...

Page 7: ...ed by SMS Received SMSes with unrecognised instructions can be forwarded to the so called service number see table 1 If you are not sure whether any other text will be automatically added to the SMS on its way to David for example when using an SMS internet gate type the message like this instructions Example The SMS text 1 1 www heating on is interpreted as heating on 8 Remote operation via diall...

Page 8: ...10 Reset to factory defaults You can reset David to the factory default settings via the SMS instruction PC RST where PC is a valid access code see Table 1 Another option is to use the RESET jumper next to the SIM case a Turn the power supply off including the backup module if used b Connect the RESET jumper turn the power supply on and disconnect the jumper after about 5s Note Performing a RESET ...

Page 9: ... be applied to extend David s working range 11 3 2 Transmitting X or Y relay status to an UC 82 or AC 82 receiver Enter mode 4 on the receiver and press the XY button on David s GD 04R module This establishes a connection so that the receiver s relay status mirrors David s relay status There is no limit to the number of UC AC receivers which can be connected this way 11 3 3 Wireless device input a...

Page 10: ... the temperature in your house An A assigned thermostat controls relay X a B assigned thermostat controls relay Y This way heating control is established supplemented by the reporting described above Thermostats enrolled to C or D inputs only provide reporting Normally an A or B enrolled thermostat switches the heating via the X or Y relay so that temperature comfort is maintained However you can ...

Page 11: ...ng to steps 3 to 5 7 Your PC now has two new devices after successful installation Jablotron serial interface as a serial port COM driver and the USB device with the same name as the driver for USB 8 Install the GDLink software on your PC 9 Connect the GD 04P cable into David s digital bus connector GDLink is now ready to be started 11 4 6 Using GDLink The program allows for o Retrieval and modifi...

Page 12: ...301489 7 EN 55022 and EN 50130 4 Radio transmissions ETSI EN 301419 1 and EN 301511 Environment II indoor general 10 C to 40 C Dimensions without antenna 76 x 110 x 33 mm GSM antenna connected to SMA connector Jablotron Ltd hereby declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The original of the conformity assessmen...

Page 13: ... access code see 6 3 Example PC ARX heating on DRX heating off Function Instruction Description Factory default SMS when activated SMS when deactivated Input A Phone numbers SMS when activated SMS when deactivated Input B Phone numbers SMS when activated SMS when deactivated Input C Phone numbers SMS when activated SMS when deactivated Input D Phone numbers ON command SMS DTMF code OFF command SMS...

Page 14: ...in total n limit in the number of calls 1 to 99 exceeding the limit removes the number from the list this is reported to the service number by SMS Example LDX 777123457 31 authorises a new number for relay X control for a maximum of 31 calls empty list Erasing tel numbers authorised for relay control EDX x x x x Use EDY for relay Y x x tel number The numbers up to 50 are removed from the list Exam...

Page 15: ...xx x numeric code up to 8 digits Example CAY 1234 Instruction CAY erases the code none DTMF code to switch relay OFF 1 CDX xx x Use CDY for relay Y xx x numeric code up to 8 digits Example CDY 1234 Instruction CDY erases the code none Wireless device assignements2 see 11 3 2 a 11 3 3 LRN n xx x n x n A B C D X or Y input or output the device should be assigned to xx x device production code last 8...

Page 16: ......

Reviews: