background image

 

 

 

 

3 of 10

 

 

19549P-83 (03-17)

 

Linking 
 

Before a belt station and a gateway can be connected, they must first be 

Linked

.  As a security 

measure, the 

close-link

 feature requires devices to be in proximity of about 1 to 3 ft (0.3 to 0.9m) 

in order to successfully link.  This ensures that the units are not inadvertently linked with other 
units on the premises.

 

Linking procedure: 

1.

 

Ensure units are within 1 to 3 ft (0.3 to 0.9m) of each other. 

2.

 

Ensure the U9110-BSW is not already connected (see 

Status Indication

). 

3.

 

Simultaneously (within 1-2 sec) press and release the PTT button on the U9110-BSW and 
the gateway to link with. 

4.

 

Amber LED’s will flash on both devices.  A momentary red LED indicates a successful 
close-link. 

5.

 

Upon successful link the U9110-BSW will attempt to establish a connection with the 
gateway. 

6.

 

Upon successfully establishing connection the LED will flash green, a voice alert will be 
heard (see 

Table 1

), and user side-tone will be enabled (see 

Communication

).   

7.

 

Link and connection are now complete. 

 
Each belt station is able to be linked to only one gateway at a time.  A gateway can have up to 
five belt stations linked and be connected to four of those five at one time. 

 

Tip:

   

Once linked, the devices will not need to be linked again unless they are purged (see 

Purging

). 

 

Status Indications 

 
The power button has a multi-color LED in the center which serves as a status indication for the 
belt station.  

Table 1

 below lists these states. 

Table 1: LED Status Indication 

LED Color 

Blink Rate 

Status 

Red Solid  Initializing/power 

up 

Red 

Solid  

Close-link successful 

Red 

Any 

Low battery (approx. 1 hr remaining) 

Orange Slow 

Idle/Disconnected 

Orange Fast 

Link/Connection 

in 

progress 

Orange Solid 

PTT 

asserted 

Green Slow 

Connected 

 
In addition to the LED, the belt station provides audio feedback for certain conditions as well.  

Table 2

 below lists these conditions. 

Summary of Contents for U9110-BSW

Page 1: ...19549P 83 03 17 2016 DAVID CLARK COMPANY INCORPORATED USER MANUAL Digital Wireless Belt Station U9110 BSW P N 40992G 19 ...

Page 2: ......

Page 3: ...is apparent immediately file a claim with the carrier and notify your David Clark product supplier ELECTRICAL HAZARD Disconnect electrical power when making any internal adjustments or repairs All repairs should be performed by a representative or authorized agent of the David Clark Company STATIC HAZARD Static electricity can damage components Therefore be sure to ground yourself before opening o...

Page 4: ... W4 44002G 01 Digital Wireless Gateway becomes part of a wireless intercom system Up to four belt stations can be connected to one gateway Figure 1 Overview of Belt Station The U9110 BSW Digital Wireless Belt Station employs an adaptive SMART VOX system which does not require adjustment by the user The system automatically monitors background noise levels and detects voice ...

Page 5: ...blishing connection the LED will flash green a voice alert will be heard see Table 1 and user side tone will be enabled see Communication 7 Link and connection are now complete Each belt station is able to be linked to only one gateway at a time A gateway can have up to five belt stations linked and be connected to four of those five at one time Tip Once linked the devices will not need to be link...

Page 6: ...approximately two seconds The LED will turn red and then turn off The belt station is now powered down Auto Shut off Additionally the belt station will automatically power down if it is disconnected from its gateway for more than 30 minutes Headset In order for the U9110 BSW to be used a David Clark H9100 series headset must be connected To connect the headset align red keyways and push Pull back ...

Page 7: ...if conditions are not improved When possible the user should attempt to regain line of sight contact with the gateway When the belt station travels out of range of the gateway a voice prompt will indicate that the connection has been lost To reconnect simply move back into range and connection with the gateway will automatically be reestablished also noted by a voice prompt PTT The PTT button allo...

Page 8: ...cinity and you wish to link a belt station to a different gateway A belt station can be linked to only one gateway at a time Purge Procedure 1 Power down belt station see Power up Power down 2 Press and hold PTT button Do not release 3 Power up the belt station see Power up Power down 4 Release POWER button when red LED turns off 5 Release PTT button 6 A voice prompt will indicate that the connect...

Page 9: ...tery is installed Cannot link a belt station Review Registration procedure Ensure units are within 1 to 3 ft 0 3 to 0 9m of each other while linking No sidetone Not connected to a Gateway Low receive audio Adjust left right volume knobs on headset No audio intermittent audio Check headset connection to belt station Replacement Parts Battery P N 40688G 90 Protective skin black A99 01SKN P N 40796G ...

Page 10: ...in direct sunlight or high temperature environments Specifications Frequency Range 1920 MHz 1930 MHz U S and Canada Average RF Power Output 4 mW 100mW peak U S and Canada Range 300 ft 100m line of sight nominal Battery Life 24 hrs continuous use nominal Operating Temperature 14 F to 113 F 10 C to 45 C Storage Temperature 4 F to 140 F 20 C to 60 C Power Requirements 3 7V 100mA nominal Battery Type ...

Page 11: ... with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio television reception Industry Canada Statement This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this d...

Page 12: ... is designed to meet the relevant guidelines for exposure to radio waves This device has been evaluated for and shown compliant with the FCC and IC RF Exposure limits The unit of measurement for RF exposure is Specific Absorption Rate SAR The highest SAR value for this product when tested for use on the body is 0 01W kg averaged over 1g SAR data information for residents in countries that have ado...

Reviews: