4

4. Prime should establish almost immediately with a 

strong flow of water, however, in some installations 

it may be necessary to repeat the above operation 

to remove all air from the system.

 

WARNING:

DO NOT RUN DRY.

DO NOT RUN WITH LOSS OF PRIME.

DO NOT PUMP WATER CONTAINING 

ABRASIVE MATERIALS.

SPECIAL MODELS

XF models fitted with “THERMOTECTION”

XF92F, XF171F, XF221F, XF192F, XF92S, XF171S, 

XF221S AND XF192S

Special models of XF pumps are supplied with a 

unique device (Thermotection) to automatically 

stop the pump should the water in the casing 

reach 85°C. This condition may occur when a fully 

primed pump is operated without being allowed to 

discharge water (i.e. closed head operation). Twin 

impeller models also have high grade 316 stainless 

steel casings.

CAUTION: 

Thermotection will automatically 

restart the pump when the water 

temperature drops below 65° ±  C 5°C.

XF models fitted with Silicon Carbide Seals

XF92B, XF171B, XF221B and XF192B

XF92S, XF171S, XF221S and XF192S

These models are fitted with special hard face 

silicon carbide mechanical seals to allow them to 

better handle corrosive and abrasive water.  Twin 

impeller models also have high grade 316 stainless 

steel casings.

DO NOT RUN DRY

WARNING: If these models are operated 

without water the mechanical seals will 

emit a high pitched noise.  Continued 

operation without water may result in 

damage to the seal chamber.

XF model with Chemical Resistant Pump End

XF171D

This model is fitted with pump components made 

from a special plastic. This model is better suited 

to pump certain chemical solutions such as those 

used in “dog spa’s”. For more information on 

acceptable chemicals contact your Davey dealer or 

the Davey Customer Service Centre.

TROUBLE SHOOTING CHECK LIST

MOTOR OPERATING BUT NOT PUMPING:

1. Suction line and pump body not filled with water.

2. Leaking foot valve.

3. Air leaks in suction lines or suction pipe not 

under water.

4. Air trapped in suction lines (also possible with 

flooded suction) due to uneven rise in piping 

(eliminate humps and hollows).

5. No water at source or water level too low.

6. Valve on suction or delivery lines closed.

MOTOR NOT RUNNING:

1. Power not connected.

2. Supply voltage too low.

3. Overload tripped.

4. Motor not free to turn e.g. a blocked impeller.

5. Internal motor fault.

*NOTE:  For protection, the Davey pump 

motor is fitted with an automatic reset 

thermal overload, constant tripping of 

this overload indicates a problem e.g. low 

voltage at pump, excessive temperature 

(above 50°C) in pump enclosure.

Warning: Automatic reset thermal 

overloads will allow the pump to restart 

without warning. Always disconnect the 

pump motor from the electrical supply 

before maintenance or repairs.

WARNING: When servicing or 

attending pump, always ensure power 

is switched off and lead unplugged. 

Electrical connections should be 

serviced only by qualified persons.

Care should also be taken when servicing 

or disassembling pump to avoid possible 

injury from hot pressurised water. Unplug 

pump, relieve pressure by opening a tap 

on the discharge side of the pump and 

allow any hot water in the pump to cool 

before attempting to dismantle.

IMPORTANT:  DO NOT USE petroleum 

based fluids or solvents (e.g. Oils, 

Kerosene, Turpentine, Thinners, etc) 

on the plastic pump components or 

seal components.

WARNING: Do not use hydrocarbon 

based or hydrocarbon propelled 

sprays around the electrical 

components of this pump.