*NOTE: For protection, the Davey pump motor is fitted with an 

automatic “over temperature” cut-out.  Constant tripping of this 

overload device indicates a problem eg. low voltage at pump, 

excessive temperature (above 45

o

C) in pump enclosure.

Care should also be taken when servicing or disassembling pump 

to avoid possible injury from hot pressurised water.  Unplug 

pump, relieve pressure by opening a tap on the discharge side 

of the pump and allow any hot water in the pump to cool before 

attempting to dismantle.

During servicing, use only approved, non-petrochemical based 

oring and gasket lubrication.  If unsure, consult your Davey 

Dealer for advice.

WARNING: When servicing or attending pump, always ensure 

power is switched off and lead unplugged.  Electrical connections 

should be serviced only by qualified persons.

WARNING: Do not use hydrocarbon based or hydrocarbon 

propelledsprays around the electrical components of this pump.

In accordance with AS/NZS 60335.2.41 we are obliged to inform 

you that this pump is not to be used by children or infirm persons 

and must not be used as a toy by children.

Summary of Contents for Weekender XP

Page 1: ...Davey Weekender XP Home Pressure Systems Please pass these instructions on to the operator of this equipment NOTE Prior to installation remove the inlet and outlet pipe transport plugs associated seals from the suction and or discharge ports ...

Page 2: ... contact your Davey dealer or the appropriate Davey office as listed on the back of this document Congratulations on your purchase of a high quality Australian built Davey pressure pump All components have been designed and manufactured to give trouble free reliable operation Before installing your new system please read all instructions carefully as failures caused by incorrect installation or op...

Page 3: ...ow when pumping longer distances Power Connection Connect lead to power supply designated on pump label do not use long extension leads as they cause substantial voltage drop poor pump performance and may cause motor overload Use unions at pipe connections to enable easy removal and servicing Use sufficient tape to ensure airtight seal and hand tighten only To prevent strain on pump threads always...

Page 4: ...off pump and unplug it from power point 2 Remove pressure switch cap 3 Turn Adjusting screw A 1 2 turn anticlockwise 4 Replace cap and switch on pump 5 If pump cuts out repeat steps 1 2 and 3 Adjustment is now complete 6 If pump does not cut out after step 4 repeat steps 1 to 5 IMPORTANT For Automatic Pressure Pumps Installed with a Mains Pressure Hot Water System Use gate valves for flooded sucti...

Page 5: ...s or damage resulting from incorrect or unauthorised installations When used with a Float Valve Where your pressure system is required to discharge through float valves filling tanks the possibility of excessive cycling may occur This can be overcome by fitting a larger Davey Supercell pressure tank in place of the Supercell tank supplied Priming and Operation 1 Fill pump and suction line On 3 Ens...

Page 6: ...and pump body not filled with water 2 Air leaks in suction lines or suction pipe not under water 3 Air trapped in suction lines also possible with flooded suction due to uneven rise in piping eliminate humps and hollows 4 No water at source or water level too low 5 Valve on suction lines closed b Pump Switches On and Off Frequently Cycling 1 Check that tank air charge is 130kPa 19 psi 2 Rapid cycl...

Page 7: ...hot water in the pump to cool before attempting to dismantle During servicing use only approved non petrochemical based oring and gasket lubrication If unsure consult your Davey Dealer for advice WARNING When servicing or attending pump always ensure power is switched off and lead unplugged Electrical connections should be serviced only by qualified persons WARNING Do not use hydrocarbon based or ...

Page 8: ...igned or advertised failure to properly follow the provided installation and operating instructions failure to carry out maintenance corrosive or abrasive water or other liquid lightning or high voltage spikes or unauthorised persons attempting repairs Where applicable your Davey product must only be connected to the voltage shown on the nameplate Your Davey Two Year Guarantee does not cover freig...

Reviews: