background image

7

POWER

Press for ON / OFF.  GREEN LED indicates power ON

.  

Leave on in winter for daily auto purge.

TEMPERATURE 
DISPLAY SCREEN

Displays temperature readout for pool and roof sensors and 
the SET comfort temperature.

DISPLAY MODE

Press D to cycle through displays of POOL, ROOF & SET 
temperature. The SET display is temporary and will revert to 
POOL after a few seconds.

TEMPERATURE 
SET

Press D to select SET. Use 

5

 or 

6

 to adjust to desired com-

fort temperature. The SET display is temporary.

SOLAR PUMP

Press for Auto or Manual operation. 
GREEN LED indicates auto run and RED LED indicates 
manual run.

Tropical (T) Mode:

 Press to Auto-Tropical mode for over-

night cooling.

PUMP RUN LED

Indicates solar pump is ON:
LED will be illuminated RED when - 

• In Auto-Normal (N) Mode:

  

The ROOF temperature is greater than the POOL 
temperature and the POOL temperature is below the SET 
comfort temperature. The pump will run to heat pool.

• In Auto-Tropical (T) Mode (For overnight cooling):

   

The ROOF temperature is less than the POOL temperature 
and the POOL temperature is above the SET comfort tem-
perature. The pump will run to cool pool.

• SOLAR PUMP has been activated manually

NOTE:

 A RED flashing LED indicates no flow to the solar 

pump, if the optional flow switch is fitted or that the blank 
flow sensor is loose or removed.

Summary of Contents for SolarMatic

Page 1: ...Solar Pool Heating Controller Installation and Operating Instructions Please pass these instructions on to the operator of this equipment...

Page 2: ...etre pool temperature cable with black connector and brass sensor 1 x 25 metre roof temperature cable with red connector and plastic sensor 1 x Blank flow connector 2 x Mounting Screws with wall plugs...

Page 3: ...cement render can damage aluminium if in doubt seal the wall before mounting the control unit Drill pilot holes and fit screws provided 3 Mount unit via top moulding of the SolarMaticTM unit Slot in b...

Page 4: ...er P N M6522 3 Fit blank flow connector to the socket marked FLOW Congratulations You are now the proud owner of the advanced SolarMatic Solar Pool Heating Controller SolarMatic extends your swimming...

Page 5: ...re switch between pump and filter The pressure switch should be tapped into a point where the pipe enters a fitting to allow a good thread length Tap size is 1 8 NPT Take care not to damage threaded e...

Page 6: ...d it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard 4 Instrument Panel Displays Feat e flow fault being rectified or wait for a ma...

Page 7: ...es auto run and RED LED indicates manual run Tropical T Mode Press to Auto Tropical mode for over night cooling PUMP RUN LED Indicates solar pump is ON LED will be illuminated RED when In Auto Normal...

Page 8: ...ng to go below 5 C When this occurs the unit will register a false warning rr to check the ROOF sensor wait for the day to warm up before taking any action ECO Mode This feature will reduce unnecessar...

Page 9: ...e back on or the first solar pump operation to reset To reset this function simply turn the solar pump ON and OFF manually at approximately the time you would like the Auto Purge function to run the p...

Page 10: ...tion Action No power to unit Mains power outlet switched OFF Turn ON SolarMatic not plugged into mains power outlet Connect plug SolarMatic controller not ON Press POWER Button ON Problem 4 Pool not h...

Page 11: ...ur receipt as proof of purchase you MUST provide evidence of the date of original purchase when claiming under the Davey One Year Guarantee Davey shall not be liable for any loss of profits or any con...

Page 12: ...12 MOUNTING TEMPLATE 18 mm...

Reviews: