5
Installation of the PowerMaster ECO Series Pumps:
Location
The pump should be located as close to the water as practicable and
mounted on a firm base in a well drained position, high enough to prevent
any flooding. It is the installer’s/owner’s responsibility to locate the pump
such that the nameplate can be easily read and the pump can be readily
accessed for service.
Weather Protection
It is recommended that the pump is protected from the weather. Enclosures
should be ventilated to prevent condensation build-up and allow a free flow
of air for the fan cooled motor.
Power Connection
Davey PowerMaster ECO is suitable for connection to a nominal 220-240
volt 50Hz power supply and are equipped with a flex and 3 pin plug. If a
power outlet is not available within 3 metres of the pump, a 3 pin power
point in a safe, dry place may need to be provided by an electrician.
Extension cords are unsafe around pools - and should be avoided. If the
supply cord of this product is damaged it must be replaced by the dealer or
manufacturer, with genuine Davey spares.
This PowerMaster Eco Series pump incorporates motor overload detection
designed to protect the motor from overheating. If the motor gets too
hot during operation, it’s operating speed will reduce to bring it within an
acceptable operating temperature and then will speed up to the originally
set speed.
To reset the motor, switch the power off for 30 seconds, and then return the
power from the mains switch not the “STOP” button on the speed selection
panel.