Installation of the ProMaster Premium VSD400 Pump:
Location
The pump should be located as close to the water as practicable and mounted
on a firm base in a well drained position, high enough to prevent any flooding. It is
the installer’s/owner’s responsibility to locate the pump such that the nameplate
can be easily read and the pump can be readily accessed for service.
Weather Protection
It is recommended that the pump is protected from the weather. Enclosures
should be ventilated to prevent condensation build-up.
Power Connection
Davey ProMaster is suitable for connection to a nominal 240 volt 50Hz power
supply and is equipped with a flex and 3 pin plug. If a power outlet is not
available within 3 metres of the pump, a 3 pin power point in a safe, dry place
may need to be provided by an electrician. Extension cords are unsafe around
pools - and should be avoided. If the supply cord of this product is damaged it
must be replaced by the dealer or manufacturer, with genuine Davey spares.
This ProMaster pool pump incorporates motor overload detection designed to
protect the motor from overheating. If the motor gets too hot during operation,
its operating speed will reduce to bring it within a acceptable operating
temperature and then will speed up to the originally set speed.
To reset the motor, switch the power off for 30 seconds, and then return the
power from the mains switch.
'DYH\:DWHU3URGXFWVUHFRPPHQGVWKDWDOOLQVWDOODWLRQVDUH¿WWHG
with earth leakage or residual current protection devices.
CAUTION: In the interest of safety, we advise that all brands and
types of pool pumps must be installed in accordance with AS3000
wiring rules or equivalent.
,IWKHSXPSDQG¿OWHUDUHORFDWHGEHORZSRROZDWHUOHYHOLWLV
QHFHVVDU\WR¿WLVRODWLQJYDOYHVLQWKHSLSHEHWZHHQWKHSXPSDQG
VNLPPHUER[DQGLQUHWXUQSLSHIURPWKH¿OWHUWRWKHSRRO
7KH¿WWLQJVRQWKLVSURGXFWDUHFRQVWUXFWHGRI$%66RPH39&
MRLQWLQJFRPSRXQGVDUHLQFRPSDWLEOHZLWK$%6&KHFNFRPSRXQG
suitability before use.
WARNING! Ensure that an electrical isolation switch is located with
easy access so that the pump can be switched off in an emergency.