20
To adjust both
ON-TIME
and
OFF-TIME
of
TIMER 2
:
70% – 09:35 AM
CHLORINE OUTPUT
Figure 12.10
> From the
HOME
screen, press
menu/setting select
;
> The display will show this screen:
MODE
1. TIMER 1
Figure 12.11
> Using the
menu up/down
buttons scroll to the
TIMER 2
menu.
MODE
2. TIMER 2
Figure 12.12
> From this screen, press
menu/setting select
to enter
TIMER 2
menu;
> To adjust both the
ON-TIME
and
OFF-TIME
for
TIMER 2
, follow the same steps shown previously
for
TIMER 1
.
12.3 ACTIVATING COVER MODE
A pool’s exposure to UV contributes significantly to the pool’s total chlorine demand. Ie the amount of
chlorine the pool uses. Excessive amounts of chlorine in a pool with a cover on, can significantly shorten the
life expectancy of the pool cover, if left for long periods of time (eg weeks). Turning on the
COVER MODE
reduces the cell duty cycle by 80% of its current setting.
For example:
• If the ChloroMatic Nipper is on for 8 hours per day, the
CHLORINE OUTPUT
is set to 50%, but the
COVER
MODE
is on: the ChloroMatic Nipper cell duty cycle is only 48 minutes, of that day;