23
• If the controls are untouched for ~ 30 seconds, the menu will revert back to normal display;
• Using the
Menu up button
and
Menu down button
scroll through to LEVEL;
• Use the
Menu up button
and
Menu down button
to change the setting to Y;
• Press the
Enter button
to save settings and return to the HOME SCREEN;
• Now restart automatic operation by pressing
Automatic on / manual off button
.
Once the menu has been changed to acknowledge the external float, the external float can be wired into
the DynaDrive controller. The normally open terminals will not trigger fault/alarm/pause conditions. When
the terminals are closed circuit, the DynaDrive operates normally. Davey recommends a float switch cable
no longer than 3m (10 feet), when using 2 x 0.25mm (24 AWG) cable. If the switch overrides DynaDrive to
pause, the DynaDrive display will show a flashing
Fault LED
.
The
Automatic LED
will also flash on the control display, see figure 7.9.
Figure 7.9
P/
N
:1
61
15
-1 B
P/
N
:1
61
15
-1 B
A 1 0
dry run
Once the switch is reversed, for example the rainwater tank filling again, the DynaDrive will restart and the
display will return to normal.