17
CHLORINE PRODUCTION
7KH$TXD5HYLYDPXVWEHUXQGDLO\WRJHQHUDWHVXI¿FLHQWFKORULQHWRVDQLWLVHWKHSRRO'XULQJ6XPPHUWKLVLV
approximately eight hours per day, preferably in two periods - between 6.00 and 8.00am and between 5.00
and 11.00pm. Night time is preferable because chlorine dissipates rapidly in direct sunlight. If these running
WLPHVDUHREVHUYHGDQGWKH&HOOLVIXQFWLRQLQJFRUUHFWO\\RXUSRROZLOOKDYHVXI¿FLHQWFKORULQHZKHQWHVWHGLQ
the morning.
If the level is too low either longer running times are required or the Sanitiser Output Control needs to be
DGMXVWHGWRPD[LPXP+DUVKORFDOFRQGLWLRQVVXFKDVWUDI¿FSROOXWLRQRUZLQGERUQHGXVWUHTXLUHGLIIHUHQW
running times, in which case, seek advice from your pool shop. During winter approximately 4 to 6 hours
DGD\VKRXOGSURYLGHHQRXJKFKORULQH:LWKRXWVXI¿FLHQW¿OWUDWLRQVDQLWLVDWLRQ\RXUSRROZLOOQHYHUIXQFWLRQ
correctly.
ALWAYS RUN THE PUMP WHEN SWIMMING IN THE POOL.
In extremely hot weather or during
periods of heavy bathing loads, the running time may need to be extended to 10 – 14 hours per day.
,QVRPHFDVHV\RXPD\¿QG\RXUFKORULQHOHYHOWREHWRRKLJK7RGHWHUPLQHLIWKLVLVWKHFDVHUXQ\RXU
¿OWHU6DQLWLVHUIRUWKHVXJJHVWHGWLPHVFKORULQHSURGXFWLRQOHYHODQGWHVW\RXUSRROZDWHURQWKHPRUQLQJ
after operation. If your chlorine test shows a high level of chlorine, either the running times can be reduced
slightly, or the Sanitiser Output Control can be turned anti-clockwise. Test your chlorine level again the
following morning at around the same time. If your chlorine level is still high, repeat the above process until
the correct level is attained.
“SHOCK” TREATMENT
Periodically, especially during extremely hot conditions, it may be necessary to boost the amount of chlorine
in your pool in order to maintain absolute sanitation of the water. This can be achieved by adding either
liquid or granulated chlorine. If granulated chlorine is added, the Cell must be checked regularly, since the
additives from this product will clog the electrodes. Alternatively, extend the running time of your AquaReviva.
CHLORINE TYPES AND COMPARISONS / MAX POOL SIZE
0DQ\6DQLWLVHUPDQXIDFWXUHUVFDOLEUDWHWKHLUXQLWVWRFRPSDUHZLWKJUDQXODWHGFKORULQHPDNLQJLW
necessary to adjust their readings to a lower level in order to determine true chlorine production. Below is a
comparison table of the available types of chlorine used to sanitise pools.
AquaReviva
Model
Production
Maximum
(g/hr 100%)
Production
(g/hr 65%
equivalent)
Chlorine
produced
over
8 hours
(grams 100%)
Maximum Pool Size (Litres)
Cool
Climates
<25ºC
Temperate
Climates
25ºC to 30ºC
Hot & Tropical
Climates
>30ºC
DAR14C
14
22
112
70,000
43,000
30,000
DAR20C
20
31
160
100,000
62,000
44,000
DAR26C
26
40
208
130,000
81,000
57,000
NOTE: The appropriate Sanitiser size for your pool is dependent on the local
climate and the bather load of the pool. Please note that Sanitiser cell life
can be increased with shorter running times during winter and lower output
settings. Davey recommends that a Sanitiser is run for between 6 - 8 hours a
day during summer, and 4 hours during winter.
403165_AquaReviva_I&OI.indd 17
4/7/17 9:18 am