background image

PRODUCT GUARANTEE (NEW ZEALAND)

Steriflo

®

systems, except for lamps, are guaranteed for a period of one year from the date of original

purchase to be free of material or manufacturing defects. Should any part fail as a result of such defects
within this period, the pressure system will be repaired free of charge. Additionally, a one year pro-rata,
parts only guarantee commencing from the date of original purchase shall apply only to the lamp.

TERMS AND CONDITIONS

1.

This guarantee applies to all states and territories of Australia and New Zealand only and is subject to
the provisions of the Trade Practices Act (Aust.), the Goods and Consumer Protection Legislation of
the various Australian states and the Consumers Guarantee Act 1993 (NZ) as applicable.

2.

The guarantee period commences on the date of original purchase of the equipment. Evidence of
this date of original purchase must be provided when claiming repairs under guarantee. It is
recommended you retain all receipts in a safe place.

3.

This guarantee covers parts and workshop labour only. Goods should be forwarded, with proof of
date of original purchase, to an Authorised Davey Service Centre in Australia or Davey Water Products
Limited in New Zealand, freight paid.

4.

The pro-rata lamp guarantee is calculated on a monthly basis, up to 12 months.

5.

This guarantee is subject to due compliance by the original purchaser with all directions and
conditions set out in the Installation and Operating Instructions. Failure to comply with these
instructions, damage or breakdown caused by fair wear and tear, negligence, misuse, incorrect
installation, chemical or additives in the water, inadequate protection against freezing, rain or other
adverse weather conditions, corrosive or abrasive water, lightning or high voltage spikes or through
unauthorised persons attempting repairs are not covered under guarantee. The product must only be
connected to the voltage shown on the nameplate.

6.

Without limiting the original purchaser’s entitlements under the Trade Practices Act (Aust.), the Goods
& Consumer Protection Legislation of the various Australian states, or the Consumers Guarantee Act
1993 (NZ), Davey shall not be liable for any loss of profits or any consequential, indirect or special
loss, damage or injury of any kind whatsoever arising directly or indirectly from the product or any
defect.

7.

Where the Trade Practices Act (Aust.), the Goods and Consumer Protection Legislation of the various
Australian states and the Consumers Guarantee Act 1993 (NZ) does not apply, Davey shall not be
liable for any loss of profits or any consequential, indirect or special loss, damage or injury of any kind
whatsoever suffered by the purchaser arising directly or indirectly from the product or any defect and
the purchaser shall indemnify Davey against any claim by any other person whatsoever in respect of
any such loss, damage or injury.

8.

Nothing in this guarantee is intended to have the effect of contracting out of the provisions of the
Trade Practices Act (Aust.), the Goods and Consumer Protection Legislation of the various Australian
states and Consumers Guarantee Act 1993 (NZ) except to the extent permitted by the various Acts
and this guarantee is to be modified to the extent necessary to give effect to that intention.

9.

Davey may be collecting personal information from you in order to provide you with a service. Davey
Water Products Pty Ltd promises only to use this information in accordance with the Provisions of the
Privacy Act 1988 (Cth) and the Privacy Policy of Davey Water Products Pty Ltd which is available at
davey.com.au.

® Davey and Steriflo are registered trademarks of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2011.

P/N 401915/0511/NZ

Davey Water Products Pty Ltd

Member of the GUD Group

ABN 18 066 327 517

AUSTRALIA

NEW ZEALAND

REST OF WORLD

Head Office and Manufacturing

7 Rockridge Avenue,

6 Lakeview Drive,

6 Lakeview Drive,

Penrose, Auckland 1061

Scoresby, Australia 3179

Scoresby, Australia 3179

Ph: +64 9 570 9135

Ph: +61 3 9730 9121

Ph:

+61 3 9730 9222

Fax: +64 9 527 7654

Fax: +61 3 9753 4248

Fax:

+61 3 9753 4100

Website: daveynz.co.nz

E-mail: [email protected]

Website: davey.com.au

E-mail: [email protected]

Website: davey.com.au

Customer Service Centre

Customer Service Centre

Ph:

1300 369 100

0800 654 333

Fax:

1300 369 119

E-mail:

[email protected]

Summary of Contents for Steriflo UV50

Page 1: ...Maximum operating pressure for stainless steel UV chambers is 860kPa 125 psi If this pressure can be exceeded or if operating close to this pressure fit a suitable pressure limiting valve in the supply to the UV chamber If any electrical supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not i...

Page 2: ...on Page 5 Electrical Power Surge Protection Page 5 6 Pipe Connections Page 6 Pre treatment drinking water Page 6 Lamp Installation Page 7 Operation Page 7 Maintenance Page 8 9 Water Quality Page 9 Lamp Fail Alarm Page 9 Trouble Shooting Page 10 Specifications Page 10 Spare Parts Page 10 Warning UV Radiation Page 11 After Sales Service Page 11 ...

Page 3: ...uctions carefully as failures caused by incorrect installation or operation are not covered by the guarantee Your Ultra Violet water treatment system is designed to handle clean water free of particulate matter The system should not be used for any other purpose without specific referral to Davey Water Products The use of the system with flammable corrosive and other materials of a hazardous natur...

Page 4: ...uring servicing Leave a chamber lengths space at the lamp connector end for lamp removal Installation can be horizontal outlet facing upwards or vertical outlet horizontal Housing your Steriflo System To protect your Steriflo system from the weather make sure the site is water proof frost free and has adequate ventilation Allow for drainage to avoid damage to flooring etc that over time may occur ...

Page 5: ... only work when unit is connected to the correct electrical supply Install the power supply enclosure above the treatment chamber so that in the event of a leak water cannot drip down the lamp lead into the enclosure CAUTION The supply cord is necessary for lamp changing The three pin supply plug must remain accessible after installation If installed to fixed wiring without the plug a two pole swi...

Page 6: ...lows If flows may exceed the design maximum install a flow restriction device Use unions at pipe connections to enable easy removal and servicing Use sufficient tape to ensure airtight seal and do not over tighten To prevent strain on unit threads always support heavy inlet and outlet pipes Pre treatment drinking water Prefiltration is usually required to ensure that particulate matter does not sh...

Page 7: ...ith the screws provided Operation Once all leak testing and lamp fitment has been completed prime pump and connect pump lead to supplied outlet Connect three pin plug to power outlet and switch on Open valves and allow water to fill the chamber The Mains On Amber LED will be illuminated and the red alarm light will flash slowly Note If chamber does not fill with water within two minutes reprime th...

Page 8: ...ir the UV output The quartz sleeve should be removed after one month and inspected for deposits Clean with methylated spirits 5 hydrochloric acid if heavily fouled and carefully dry Handle the sleeve with tissue to keep it clean The sleeve should be cleaned every three months or as required Sleeve removal use care fragile 1 Remove lamp as described 2 Remove drain port cap and empty water from cham...

Page 9: ...replaced as required to maintain them in good condition UV transmissibility UVT of the water can be tested by your local dealer or by undertaking an appropriate water test Lamp Alarm System If the UV lamp is out due to a failure or bad connection the alarm buzzer will sound and the flashing red LED will light continuously The alarm will disconnect power to the pump lead preventing untreated water ...

Page 10: ... short in lamp circuit Specifications Flow range UV50 0 50 l min Flow range UV70 0 70 l min Water temperature range 8 35o C Water pressure 0 860 kPa Operating voltage frequency 220 240v 50Hz Power consumption 45 W Lamp life 9 000 hours 1 year s running Spare Parts Lamp GPH550N2W Sleeve TT600 End nut S333A Cover plate S334A Lamp connector and lead S486 Oring S24x3N70 White pressure ring S113 WARNIN...

Page 11: ...l hours later Severe exposure sore red eyes sensitive to light painful to keep eyes open SKIN Mild exposure slight reddening tenderness mild sunburn symptoms Severe exposure skin sloughing peeling weeping area sever sunburn symptoms FIRST AID EYES In mild cases if in doubt seek medical attention Severe cases cover eyes with gauze or clean cloth seek medical attention SKIN In mild cases removal fro...

Page 12: ...islation of the various Australian states or the Consumers Guarantee Act 1993 NZ Davey shall not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever arising directly or indirectly from the product or any defect 7 Where the Trade Practices Act Aust the Goods and Consumer Protection Legislation of the various Australian states and t...

Reviews: