background image

Congratulations

on choosing Spa-Quip’s top of the line Spa Power control system.

Page 1

1.1 Basic Operation

The SP1200 touch pad features a large display consisting of four numerical digits and

. The display

typically shows three quantities - Current pool temperature,

and

By default the current pool temperature is displayed on the numerical digits leaving the clock and set

temperature on the two lines of text. This configuration may be changed by the user if a different layout is preferred.

Whenever a touch pad button is pressed the two lines of text will temporarily describe the newly selected state.
Likewise when the controller is busy performing a task, text will be displayed to explain what is happening (examples
include sleeping, purging pumps and water priming). Each of these messages and the associated function is
described in the following sections.

two lines of text

Set (Target) pool temperature

clock (weekday and

time).

This controller offers a large range of possible accessories, a user friendly touchpad and superior components. It
makes use of the latest electronics, display and sensor technology to provide you with the most sophisticated
controller in its class.

1 Introduction

36.75

Mon,

12:00

PM

C

Set temp

37.00

O

Light Effect Mode

Pump 1A

Pump 1B

Aux

Light Level

Variable Speed Blower

Pump 2A

Pump 2B

Auto LED / Water LED

Heater LED

Ozone LED

Sleep LED

Down

Up

Scroll

1.2 SP1200 Touchpad

(SPVSB)

Page 32

When in an error state the alarm can be silenced by pressing the SCROLL button. The alarm will
automatically silence after four minutes.

Error 1 (“PRIME FAILED”) Water Prime Failed
Prime failed is a special case. This is not necessarily a problem with the SP1200 itself, but indicates that no
water is being detected in the heater housing. On a push of the DOWN button the main pump will run for 10
seconds to try to get water to the heater. If successful normal operation will resume. If unsuccessful, the
error will be indicated on the display again. Note: When this error occurs you will also be given the option to
run the SP1200 in demo mode, this feature is not intended for end users. If you inadvertently enter demo
mode, reset the spa to start over.

With any Error 3-8, spa operation will stop and not continue until the controller is reset. The controller can
only be reset by pushing the Light Level, Light Effect Mode, Pump 1A and Pump 2A buttons simultaneously.
The controller will remain in an error condition even when reset at mains power, controller will only continue
normal operation after the Light Level, Light Effect Mode, Pump 1A and Pump 2A buttons are pushed
simultaneously (see below).

Error 4 (“NO WATER SENSOR”) - No Water Sensor
This error indicates a problem with the optical water sensor in the heater. The problem may be caused by the
sensor being disconnected or by damage to the sensor. Try to reset the spa. If there is still a problem then
contact your spa pool supplier.

Error 3 (“STUCK BUTTON”) - Stuck Button
This error indicates that one or more of the touch pad buttons is stuck or has been held down for more than
one minute. This may be caused by the pool cover pressing on the touch pad or by water getting into the
touch pad or by damage to the touch pad itself. Try to reset the spa. If there is still a problem then contact
your spa pool supplier.

36.75

Mon,

12:00

PM

C

Set temp

37.00

O

The Spa Power 1200 controller has extensive self diagnostic capabilities. In the event of a
problem it will indicate a warning or error according to the nature of the problem. The spa will
continue operating if a warning is produced but user intervention or service is required for errors.

9 Self-Diagnostic Error Codes

Errors

Summary of Contents for SP1200-35

Page 1: ...y to the above values to ensure a healthyexperiencebothforyouasbathersandforyourspapoolequipment Damage to the element thermostat pockets and associated metalwork due to the poor maintenanceofwaterchemistryisnotcoveredbywarranty PH Models SP1200 35 1ph 3ph SP1200 45 SP1200 60 1ph only Davey Water Products Pty Ltd Member of the GUD Group ABN 18 066 327 517 Head Office and Manufacturing 6 Lakeview D...

Page 2: ...ill a problem then contact your spa pool supplier Error 6 THERMAL CUT OUT Thermal Cut Out Tripped This error indicates that the safety electromechanical over temperature cut out on the heater has operated This is not necessarily a problem with the SP1200 It may have occurred from an air lock around the element high temperatures during shipping or pump failure This automatic cut out will only reset...

Page 3: ...g detected in the heater housing On a push of the DOWN button the main pump will run for 10 seconds to try to get water to the heater If successful normal operation will resume If unsuccessful the error will be indicated on the display again Note When this error occurs you will also be given the option to run the SP1200 in demo mode this feature is not intended for end users If you inadvertently e...

Page 4: ...ng any water in the heater housing If no water is being detected the LCD Display will also show WATER PRIMING PLEASE WAIT Heater This LED shows when the heater is on The heater will turn on and off as required whenever the pump is running The LED is red when the heater is on high and orange when on low The low setting is used for load shedding to keep the total controller load within safe limits w...

Page 5: ... touch pad LCD contrast brightness can be manually adjusted if the display appears too dark or light To adjust the contrast follow these steps 1 Press and hold down the LIGHT button This will cycle the light intensity as usual however you must keep the button held down before proceeding with the following steps 2 With the LIGHT button held down press the UP or DOWN buttons to darken or lighten the...

Page 6: ...ion please see section 3 9 LD DEFAULTS SET NO ARE YOU SURE Push 9 Scroll to SET NO YES 1 SET TEMP 2 USER TIMER 3 CLOCK 4 USER ALARM 5 SLEEP TIMES 6 MAINT TIMERS 7 MISC OPTIONS 8 ADV OPTIONS 9 LD DEFAULTS Page 29 Select MAIN menu then push UP button nine times 7 10 Load Factory Default Settings The load defaults option provides a way of restoring all factory default settings These include obvious s...

Page 7: ...n hour to ensure filtration times are met similarly a setting of 4 hours indicates that a filtration run will occur once every 4 hours 1 Select the ADV OPTIONS submenu from the main menu 2 Select the FILT TIME menu item 3 Press the SCROLL button to begin Filtration Period modification 4 Use the UP and DOWN buttons to set the desired filtration period 5 Press the SCROLL button to confirm the curren...

Page 8: ... the controller will attempt to use the high setting whenever heating is required Note that high heat may not always be available due to possible load shedding when accessories are turned on depends on installer configuration Range of adjustment is 0 00 default off to 5 00 in steps of 0 25 degrees Celsius At the maximum setting of 5 00 the pool water must be five or more degrees below the set temp...

Page 9: ...tton modify light synchronisation setting 4 Use the UP and DOWN buttons to toggle between on and off 5 Press the SCROLL button to set Note This option is only available if a SPVCL Spa Power Variable Colour Light is in the pool Page 7 3 3 Pump 1 Two speed 24HR circulation pump fitted This pump is controlled via two touch pad buttons one to turn the pump on off and another to change its speed The mo...

Page 10: ...s of touch pad inactivity no button presses the backlight intensity will automatically return to a fixed 34 setting This is to ensure long life of the backlight LEDs As soon as you press a button on the touch pad your custom setting will be restored 1 Select the MISC OPTIONS submenu from the main menu 2 Select the PANEL LIGHT COLOUR menu item 3 Press the SCROLL button to begin light colour selecti...

Page 11: ... touch pad inactivity The Air Button controls a Spa Power Variable Speed Blower if fitted It is used to turn the blower on off and select different operating modes Four pushes of the air button cycle the blower as follows 5 1 Adjustable Speed Mode SPVSB In the adjustable speed mode the UP and DOWN buttons are used to set the blower to one of 9 different speeds On the first press of UP or DOWN the ...

Page 12: ...no SPVCL is fitted then the buttons can still be used to produce lighting effects on the touch pad as though a light was fitted The Light Level button selects the intensity of the light and the Light Effect Mode button selects the light colour and effect Pressing the UP or DOWN button while in high medium or low mode will automatically change to adjustable mode 6 1 Adjustable Light Intensity Mode ...

Page 13: ...the available colours one at a time without any smooth fading between different colours The UP and DOWN buttons may be used to change the speed of the light effect see section 6 2 1 below LCD Displays DELAYED CHANGE Light cycles through all of the available colours one at a time Each colour is shown for a short period then the light will quickly fade to the next colour The UP and DOWN buttons may ...

Page 14: ...splay Notes 1 For correct sleep operation ensure the clock is set correctly You will need to set it the first time the controller is powered up or if the controller has been turned off for a long period 2 The maximum possible sleep time for one period is 23 hours 59 minutes This is achieved when the stop time is one minute before the start time If the two times are equal the sleep period will have...

Page 15: ...us Options Menu and Advanced Options Menu These sub menus are accessed via main menu items 4 to 8 respectively Simply select one of these items in the main menu and press the SCROLL button You will now be in the given sub menu Browse sub menus just as you would the main menu the interface functions exactly the same To select any other item either within the main menu or any of the sub menus simply...

Page 16: ...ery handy feature that is used to silence the spa pool during your hours of sleep While the SP1200 is asleep no automatic heating or filtration maintenance will occur however the spa can still be used in manual mode without having to change any settings There are a total of nine individual sleep times that can be programmed each of which can operate on one or more specified weekdays You may use as...

Page 17: ... timer by pressing SCROLL again Otherwise wait approximately five seconds for the message to disappear and you will be returned back to the default view with the timer running in the background 7 4 Clock The SP1200 contains a real time clock that will retain the correct time even during short power cuts The clock provides the user with a convenient way to tell the time in the pool and is also used...

Page 18: ...2 USER TIMER 3 CLOCK 4 USER ALARM 5 SLEEP TIMES 6 MAINT TIMERS 7 MISC OPTIONS 8 ADV OPTIONS 9 LD DEFAULTS Page 17 Select MAIN menu then push UP button four times 7 5 User Alarms The SP1200 controller has nine user programmable alarms that you can configure to go off at a preset time while you are using the spa These alarms function similarly to a regular clock alarm but with the additional benefit...

Reviews: