Control Panel Layout:
Once the salt level in the pool is correct the Unit may be switched On.
(Note: Once the
unit starts there is a short time delay until the cell operates to ensure filtration
system is primed with water)
At this point the
Operation LED
should be Green; if red
refer below. Note: Polarity LED may be either A or B (whichever is on or brightest).
The RED Operation LED will indicate a number of different possible problem situations:
Possible Problem
Action
Salt Level Below Minimum
Add Salt
Cell is Calcified
Clean Cell
Water temperature very cold
Add salt to compensate for cold water
There is a problem with water flow
Check pump / pipes for blockage or damage.
Check that flow sensor is connected properly
and in the right direction.