Operational characteristics
This section describes the operational characteristics including:
●
PSU input range that can be configured in several ways
●
Power consumption
●
Heat dissipation
8.1
PSU input range
8.1.1
PSU input configuration 0,1
Parameter
Min
Typ
Max
Unit
Main power supply voltage
3.135
3.3
3.465V
8.1.2
PSU input configuration 2
Parameter
Min
Typ
Max
Unit
Main power supply voltage
3.3
3.7
4.5V
8.1.3
PSU input configuration 3
Parameter
Min
Typ
Max
Unit
Main power supply voltage
3.25
3.3
3.465V
8.2
Power consumption
Providing theoretical maximum power consumption value would be
useless for the majority of system designers building their application
upon
AXEL ULite
module because, in most cases, this would lead to an
over-sized power supply unit. Several configurations have been tested in
order to provide figures that are measured on real-world use cases
instead. Please note that
AXEL ULite
platform is so flexible that it is
virtually impossible to test for all possible configurations and applications
on the market. The use cases here presented should cover most of real-
world scenarios. However actual customer application might require more
power than values reported here. Generally speaking, application specific
requirements have to be taken into consideration in order to size power
August, 2019
61/65
Summary of Contents for Axel ULite
Page 2: ...AXEL ULite Hardware Manual v 1 0 2 Page intentionally left blank August 2019 2 65...
Page 6: ...AXEL ULite Hardware Manual v 1 0 2 August 2019 6 65...
Page 31: ...AXEL ULite Hardware Manual v 1 0 2 Tab 13 J2 odd pins 1 to 203 August 2019 31 65...
Page 65: ...AXEL ULite Hardware Manual v 1 0 2 Fig 7 Accessing the RESERVED AREA August 2019 65 65...