2
Connecting the supply media
Compressed air supply
2-4
DATRON AG
Setup instructions neo
1.21
2.4
Notes regarding the control computer
Observe the following points to ensure the process reliability of
the machining system and quick help in the event repairs are
needed:
■
The DATRON machine may only be operated with the control
components included in delivery. These are an integral part of
the system.
■
Do not install any other applications, and also no virus
scanners on the control components, which are not expressly
approved of by DATRON. Additionally installed applications
can lead to non-reproducible, sporadically occurring errors.
2.5
Compressed air supply
The compressed air must meet the requirements of the spindle
manufacturer (see the original spindle operating instructions).
It must be dry, clean and oil-free. Otherwise, the components
through which the air flows could be damaged (especially the
spindle).
Required air purity
Solid contaminants
Class 3
Max. particle size 5 µm
max. Particle content 5 mg/m³
Water content
Class 4
Max. pressure dew point +3 °C
Total oil content
Class 3
Max. oil content 1 mg/m³
NOTE
DATRON urgently recommends that an air treatment system be
connected in front of the system!
Any air treatment system available on the market can be used
which fulfils the above requirements. Our commissioning
personnel is instructed to use a suitable air dryer when there is
moisture in the compressed air. This is available for purchase.
If the machine is operated with insufficiently pure compressed air,
the warranty for the spindle and components through which air
flows is invalid.
Summary of Contents for neo
Page 1: ...DATRON neo Setup instructions ...
Page 4: ...i Contents i 2 DATRON AG Setup instructions neo 1 21 ...
Page 8: ...1 Setting up the machine Screen 1 4 DATRON AG Setup instructions neo 1 21 ...
Page 16: ...2 Connecting the supply media Chip suction 2 8 DATRON AG Setup instructions neo 1 21 ...
Page 24: ...5 Vacuum cleaner optional 5 2 DATRON AG Setup instructions neo 1 21 ...