2 Two-Piece Table [Continued]
2.2 Final Table Leveling
2.2.1
Once properly positioned, verify all top and edge seams are still aligned and flush. Loosen, adjust and re-tighten Zip-Bolts
and\or Stiffeners as required if adjustments are needed. A Rubber Mallet with a block of wood to protect the table from damage
can be used if it helps. [Fig. 07]
2.2.2
Use a level to measure and adjust levelers on Ends to level the table while continually verifying that the edges and top remained
aligned. If necessary, make further adjustments to the Zip-Bolts and\or Stiffeners during the leveling process. [Fig. 07]
Note:
A gap up to 1/16" between the level and top surface where the two table halves connect can occur, especially on larger tables.
2.3 End Access Panels, Power And Connectivity
2.3.1
For installation of End Access Panels (BB), skip forward to Section 3. For installation of standard Power and Connectivity options,