8
Operation
DATEQ SPL-D3 manual
UK
Operation
1. Display 1:
Shows the actual measured dB value in green, orange or red.
2. Filter weight:
Shows the used filter weight in dBA, dBC or dB (no filter).
3. VU/Reduction bar:
Shows the actual fast PPM level in dB.
Linked to the SPL-5MK2 or SPL6 the VU meter can also be used to show selected Leq or
reduction level of the limiter.
4. Displays 2 and 3:
Shows the actual measured dB value in green, orange or red.
Both displays can be selected with an independent value/ filter.
5. Leq/min:
Shows the used time frame for Leq. In this example 10 minutes for display 2 and 60 minutes for
display 3.
6. USB-A connection:
Allows an external FAT32 drive to export measurement data from past 30 days.
7. Push button:
Allows to export measurement data to external FAT32 drive, display SPL-D3 IP address or
reset the SPL-D3 IP address.
8. Seal:
Allows to seal the cable cover using two M4 screws and a cable seal.
Summary of Contents for SPL-D3
Page 1: ...SPL D3_200101_V1 0EN SPL D3 Multi Color Display Sound level logger Manual ...
Page 12: ......
Page 13: ...SPL D3 Multi Color Display Sound level logger Configuration ...
Page 14: ...Notes ...
Page 24: ...24 Installation DATEQ SPL D3 manual UK ...