3.  Model Selection & Energy Conservation:

 In order to achieve the lowest 

possible energy consumption, be sure to determine your application’s total 
current requirements. This is especially true when using DMS-PS-CM 
supplies to power DATEL’s energy-efficient LED and/or LCD display digital 
panel meters (DPMs) and process monitors. In general, choose a power 
supply that will accommodate your maximum current consumption plus a 
20% margin. Choosing the lowest-wattage model suitable for a given appli-
cation will provide lower procurement costs and lower long-term operating 
costs.

  When calculating total current requirements in installations employing 

three or more DMS-Series meters, it is acceptable practice to use each 
meter’s typical current consumption rating. However, be sure to consult 
the relevant product datasheets for all instrumentation comprising your 
application.

  For applications where DMS-PS-CM power supplies will be powering only 

Murata Power Solution’s DPM’s, a 5-Watt DMS-PS3-CM can power up 
to four, standard intensity (‘-RS’ suffix) red-LED DMS-30PC meters: two 
meters on V1, and one meter each on V2 and V3. The same DMS-PS3-CM 
could also be used to power over 40 low-power red DMS-30PC meters 
(‘-RL’ suffix), or over 800 DMS-30LCD non-backlit meters! Of course, these 
statements are made without regard to ground-loop problems that may be 
encountered when powering 800 DPM’s from a single power supply.

Application Information

1.  Chassis Mounting Considerations: 

In order to minimize self-heating,  

DMS-PS-CM power supplies should always be mounted in either a 
vertical or horizontal position. Avoid mounting units upside-down or in 
close proximity to other heat-generating devices. Also, be sure to use 
the mounting hardware described in Figure 4 below in order to ensure 
a secure, vibration-resistant installation.

Figure 4. Chassis Mounting

2.  Bipolar Operation (See Figure 5): 

DMS-PS-CM power supplies’ fully 

isolated outputs allow for the generation of bipolar (positive and nega-
tive) supply voltages. Bipolar outputs can be used to power dual-supply 
operational amplifiers, as well as any other type of instrumentation that 
requires bipolar supply voltages. However, please keep in mind that 
when connecting and operating any two outputs in this fashion, each 
output retains its maximum current rating.

COM

+24V –5V

+5V

–      +

–      +

–      +

V1 

V2 

DMS-PS6-CM

V3 

Figure 5. Bipolar Connections

Figure 6. Measuring Ripple and Noise

Panel/Chassis

Threaded

Hole

Screw,
Split Lock Washer,
Flat Washer

Panel/Chassis

Hole

Flat Washer,
Split Lock Washer,
Nut

Screw,
Flat Washer

Oscilloscope

BW = 20MHz

DMS-PS-CM

V1

+

Scope Probe

DMS-PS-CM Series

High Efficiency, AC/DC Instrumentation Power  

Supplies with Individually Isolated Outputs

MPM_DMS-PS-CM_B01

 

Page 5 of 8

Summary of Contents for DMS-PS-CM Series

Page 1: ...voltage protection A rugged vibration proof chassis mount package incorporates large shock resistant terminal blocks for all I O connections Multiple outputs low noise low cost high efficiency double...

Page 2: ...nsulation Strip Length 0 25 inches 6 4mm ScrewTighteningTorque 4 4 pound inches 0 5Nm Rated Voltage 630V VDE 0110 V Group 2 250V VDE 0110 V Group 3 EMI All models Meets CISPR Pub 22 FCC Class B Safety...

Page 3: ...cuit etch side of the pc board Fuse replacement is performed by first de energizing and then disconnecting the ac mains from TB4 Next disconnect all load wiring from TB1 TB2 and TB3 Lastly remove the...

Page 4: ...t be adjusted to within 2 of its nominal value 5 0V 12 0V or 24 0V depending on model 9 Temperature Derating See Figure 3 All DMS PS CM supplies are speci fied to operate at their full rated power ove...

Page 5: ...over 800 DMS 30LCD non backlit meters Of course these statements are made without regard to ground loop problems that may be encountered when powering 800 DPM s from a single power supply Application...

Page 6: ...formance Curves TA 25 C VIN 120V 60Hz Noise and Ripple 100 Load 20MHz Bandwidth DMS PS6 CM V1 24V DMS PS9 CM V1 24V DMS PS3 CM V2 4 85V DMS PS6 CM V2 4 85V DMS PS9 CM V2 4 85V DMS PS CM Series High Ef...

Page 7: ...EC 0 010 0 254 Transient Response 10 to 100 Load Step DMS PS3 CM V2 4 85V DMS PS6 CM V2 4 85V DMS PS9 CM V2 4 85V DMS PS3 CM V1 5V DMS PS6 CM V1 24V DMS PS9 CM V1 24V Typical Performance Curves TA 25...

Page 8: ...21 08 Murata Power Solutions Inc makes no representation that the use of its products in the circuits described herein or the use of other technical information contained herein will not infringe upo...