Datel DMS-PS-CM Series Brochure & Specs Download Page 2

Technical enquiries

 email: [email protected], tel: 

+1 508 339 3000

www.murata-ps.com

Performance/Functional Specifications

Typical at T

A

 = +25°C and V

IN

 = 85-264V @47-63Hz

 All models will also operate from a regulated and filtered 110 to 340Vdc input.

 Unless otherwise specified, load regulation is measured with the output under 

test undergoing a load change of 100% to 50% at nominal line input and, 
when applicable, with all other outputs operating at 50% of rated load.

➂ 

Transient response is defined as the output returning to within its specified 

tolerance in 10ms or less, following a 90% load change.

AC Input 

 

 

Input Voltage Range, All models 

 

85-264V @47-63Hz

Input Current 

(115V/230V, typ.):

 

 

5-Watt Models 

0.15A/0.07A

 

 

10-Watt Models 

0.3A/0.13A

 

 

16-Watt Models 

0.33A/0.16A

Inrush Current 

(All models, typical peak):

 

 

@115Vac 

14.1A

 

 

@230Vac 

32.5A

Isolation 

(Min.):

 

 

Output V1 to AC Input 

3000Vac 

 

 

Outputs V2 & V3 to AC Input 

3 1000Vdc

 

 

AC Input to Frame Ground 

1500Vac

 

 

Output V1 to Frame Ground 

500Vac

 

 

Outputs V2 & V3 to Frame Ground 

1000Vdc

 

 

Outputs V2 & V3 to Output V1 

1000Vdc

 

 

Output V2 to Output V3 

2000Vdc

Frame Ground Leakage Current 

(Max.):

 

 

@115Vac 

0.5mA

 

 

@230Vac 

3.5mA

Switching Frequency 

(Typical):

 

 

V1 

(5W and 10W models)

 

75kHz

 

 

V1 

(16W models)

 

83kHz

 

 

V2 & V3 

(All models)

 

100kHz

Line Fuse 

(Built-in)

 

1A/250Vac, 5 x 20mm, meeting  

 

IEC60127-2, sheet 3 specification  

 

for time lag fuses 

(slow-blow)

AC Mains Terminal Block 

(TB4):

 

 

Wire Size & Type 

14-20AWG (2.5 to 0.5mm

2

),  

 

 

solid or stranded

 

 

Insulation Strip Length 

0.25 inches (6.4mm)

 

 

Screw Tightening Torque 

4.4 pound-inches (0.5Nm)

 

 

Rated Voltage 

630V (VDE 0110-V. Group 2);  

 

250V (VDE 0110-V. Group 3)

EMI 

(All models)

 

Meets CISPR Pub. 22 & FCC  

 

Class B

Safety Approvals 

Pending 

DC Outputs

Line Regulation 

(All outputs)

 

±0.1% (max)

Load Regulation: 

 

 

V1 

(All models)

 

±2%

 

 

V2 & V3 

(All models)

 

±0.2% (max)

Output Accuracy 

(Max.):

 

 

V1 

(All models)

 

±2.0%

 

 

V2 & V3 

(All models)

 

±2.5%

Hold-Up Time 

(47-63Hz):

 

 

@115Vac 

20mSec. typ.

 

 

@230Vac 

80mSec. typ. 

Noise & Ripple  

(All models, 20MHz bandwidth):

 

See Noise & Ripple graphs 

 

 

V1 

40mVp-pk (typ.)

 

 

V2 & V3 

8mVp-pk (typ.) 

Transient Response 

 

See Transient Response graphs 

DC Outputs

 (continued)

Efficiency 

(Typ.@ 120Vac, full load):

 

 

Single Output Models 

75% 

 

 

Dual Output Models 

73%

 

 

Triple Output Models 

71%

DC-Output Terminal Blocks 

(TB1, TB2, TB3):

 

 

Wire Size &Type 

16-20AWG (1.5 to 0.5mm

2

),  

 

 

solid or stranded

 

 

Insulation Strip Length 

0.25 inches (6.4mm)

 

 

Screw Tightening Torque 

3.6 pound-inches (0.4Nm)

Short Circuit Protection 

(All outputs)

 

Foldback, self-recovering

Overvoltage Protection V1 

(max.)

 

134% x Vout

 

Environmental

Operating Temperature 

0 to +50°C @ full rated power;  

 

–25 to +70°C @ 50% rated power  

 

(see Figure 3)

Storage Temperature 

–40 to +85°C

Cooling 

Free air convection with derating 

 

 

(see Figure 3 and Technical  

 

Notes)

Humidity 

(Non-condensing)

 

0 to 85% 

Physical

Dimensions 

See Mechanical Specifications

Weight: 
 

5 Watt Models 

5.8 ounces (165 grams)

 

 

10 Watt Models 

6.9 ounces (195 grams)

 

 

16 Watt Models 

7.9 ounces (223 grams)

Case Materials: 
 

Outer Case 

ABS, UL94 5VA

 

 

DC/DC Modules 

Phenolic, UL94 V-0

 

 

AC/DC Modules 

Plastic, UL94 V-1

DMS-PS-CM Series

High Efficiency, AC/DC Instrumentation Power  

Supplies with Individually Isolated Outputs

MPM_DMS-PS-CM_B01

 

Page 2 of 8

Summary of Contents for DMS-PS-CM Series

Page 1: ...voltage protection A rugged vibration proof chassis mount package incorporates large shock resistant terminal blocks for all I O connections Multiple outputs low noise low cost high efficiency double...

Page 2: ...nsulation Strip Length 0 25 inches 6 4mm ScrewTighteningTorque 4 4 pound inches 0 5Nm Rated Voltage 630V VDE 0110 V Group 2 250V VDE 0110 V Group 3 EMI All models Meets CISPR Pub 22 FCC Class B Safety...

Page 3: ...cuit etch side of the pc board Fuse replacement is performed by first de energizing and then disconnecting the ac mains from TB4 Next disconnect all load wiring from TB1 TB2 and TB3 Lastly remove the...

Page 4: ...t be adjusted to within 2 of its nominal value 5 0V 12 0V or 24 0V depending on model 9 Temperature Derating See Figure 3 All DMS PS CM supplies are speci fied to operate at their full rated power ove...

Page 5: ...over 800 DMS 30LCD non backlit meters Of course these statements are made without regard to ground loop problems that may be encountered when powering 800 DPM s from a single power supply Application...

Page 6: ...formance Curves TA 25 C VIN 120V 60Hz Noise and Ripple 100 Load 20MHz Bandwidth DMS PS6 CM V1 24V DMS PS9 CM V1 24V DMS PS3 CM V2 4 85V DMS PS6 CM V2 4 85V DMS PS9 CM V2 4 85V DMS PS CM Series High Ef...

Page 7: ...EC 0 010 0 254 Transient Response 10 to 100 Load Step DMS PS3 CM V2 4 85V DMS PS6 CM V2 4 85V DMS PS9 CM V2 4 85V DMS PS3 CM V1 5V DMS PS6 CM V1 24V DMS PS9 CM V1 24V Typical Performance Curves TA 25...

Page 8: ...21 08 Murata Power Solutions Inc makes no representation that the use of its products in the circuits described herein or the use of other technical information contained herein will not infringe upo...

Reviews: