DMS-EB-AC/DC

Potentiometer R5 applies a stable, positive dc-offset voltage to the
meter’s IN LO terminal. This offset voltage has a range of 0 to +1.2Vdc,
measured with respect to TB1 terminal 2 (LO). It can be used to null (or
cancel) the effects of an input whose zero level is not exactly zero volts.
For example, adjusting R5 allows the display to read “000” with an input
whose lowest level is slightly above zero volts. Please note, R5 can not
compensate for inputs whose zero level is negative (i.e., if TB1 HI is
more negative than TB1 LO).

3.  Measuring Input Voltages Greater than 1.999Vdc (Use DMS-30-0 or

DMS-30-1 Only): If possible, the resistors used for R1 and R2 should be
±1% metal-film types with TCR’s less than or equal to 100ppm/°C. More
information on selecting 1% resistors can be found in Application Note 14
of the DATEL Panel Meter Catalog.

CAUTION: Do not apply inputs greater than +/-250Vdc.
1. Open SG10. For applications in which input voltages exceed ±100Vdc,

also cut the 2 adjoining traces.

2. Configure the DMS-EB-AC/DC for span adjust using the procedure

previously outlined.

3. Calculate values for R1 and R2 as follows:

A typical value for R1 is 1M

?

. The sum of R1 + R2 should be between

50k

?

 and 10M

?

.

R2 = (FSI x R1) / ( |Vin| - FSI)
Where:
FSI = The attenuated voltage between the meter’s (–) IN LO and (+) IN
HI pins (pins 12 and 11, respectively) needed to achieve the desired
display readings
Vin = Input signal at TB1 terminals 1 and 2, disregarding polarity

Example
Using a DMS-30-1 meter (+/-2V range), Vin is 0-5Vdc and the display
reading must be “000” to “1500”

1. Assume R1 = 1.0M

?

.

2. R2 = (FSI x R1) / ( |Vin| - FSI)

R2 = (1.500 x 1,000,000) / (5.0 - 1.500)
R2 = 428,571

?

 or 432k

?

3. Calibrate the meter using a known voltage source. Adjust R4 to

compensate for tolerances in R1 and R2.

Applications

1. Decimal Point Placement: DATEL ships the DMS-EB-AC/DC with all

decimal point solder gaps (SG1, SG2, SG3 and SG4) open. To enable a
specific decimal point, close its respective solder gap with solder. When
reassigning decimal places for subsequent applications, remember to
open any previously closed solder gaps.

Close SG1 for 1.999 (DP1)
Close SG2 for 19.99 (DP2)
Close SG3 for 199.9 (DP3)
Close SG4 for 1999.9 (DP4 on DMS-40LCD)

2. Span (Gain) and Zero (Offset) Adjustments (See Figure 3): DATEL

offers a resistor accessory kit, part number RN-DMS, consisting of 20-
turn potentiometers R4 (2K Ohms) and R5 (50K Ohms) and leaded
resistor R3 (10.5K Ohms). However, the leaded resistor supplied with the
RN-DMS accessory kit is not needed with the DMS-EB-AC/DC since it
contains a factory-installed 10.5K Ohm chip resistor. Once installed,
these potentiometers permit the span and/or zero adjustments described
in the following sections. R4 provides span adjust, while R5 applies a
positive offset to the meter’s (–) IN LO input.

Using Potentiometer R4 for Span Adjustment (DMS-30PC and DMS-
30LCD Meters Only)
1. For DMS-30-1, -2, and -3 models (+/-2V, +/-20V, +/-200V ranges):

Configuring the DMS-EB-AC/DC for span adjustment is simply a matter
of installing potentiometer R4, opening SG13, and then closing SG8,
SG11, and SG12.

2. For DMS-30-0 models (+/-200mV ranges): Span adjustment requires that

you open SG8, SG11 (if closed) and SG13 and then close SG7, SG9
and SG12. Then install R4.

Adjust span as desired. DMS-30-1, -2, and -3 span adjustment range is
typ10% and –5%. The DMS-30-0 has a much wider span adjust,
however, it should be limited to ±10% for optimum accuracy and stability.

Using Potentiometer R5 to Apply a Positive Offset to Pin 12 (-) IN LO
1. Open SG14 and close SG6.

2. Install 50K potentiometer R5.

Figure 2. DMS-EB-AC/DC Board

3

1 0 0 - 2 6 4 V a c   P O W E R   S U P P L Y   B O A R D   F O R   D M S - 3 0   M E T E R S

12

1

R3

SG3 (DP3)

SG2 (DP2)

SG1 (DP1)

SG9

SG11

SG6

SG10

SG14

SG7

SG8

SG13

SG4

SG12

TB1

TB2

HI(+)

LO(–)

AC LO

AC HI

1

2

1

2

DP4

Summary of Contents for DMS-EB-AC/DC

Page 1: ...es reliable mechanical connec tions and eliminates the need for any extra wiring harness connectors The DMS EB AC DC board includes provisions for installing several user supplied components that are required when the meter must be scaled to display non standard input ranges The DMS EB AC DC has provisions for such common applications as attenuation of high input voltages gain span and offset zero...

Page 2: ...d 2 LO 2 Grounding Isolation Because DMS 30 and DMS 40 meters are housed in a plastic case a connection to AC earth ground is not required When wired per the instructions above the DMS EB AC DC board provides a minimum of 1500V isolation between its AC supply input TB2 and its input signal TB1 However please keep in mind that in many applica tions the LO side of the input signal may be connected t...

Page 3: ...t Placement DATEL ships the DMS EB AC DC with all decimal point solder gaps SG1 SG2 SG3 and SG4 open To enable a specific decimal point close its respective solder gap with solder When reassigning decimal places for subsequent applications remember to open any previously closed solder gaps Close SG1 for 1 999 DP1 Close SG2 for 19 99 DP2 Close SG3 for 199 9 DP3 Close SG4 for 1999 9 DP4 on DMS 40LCD...

Page 4: ...n only carry currents up to 0 2A 200mA However dc currents up to 2A can be accommodated if a 20AWG jumper wire is soldered in location R1 Be sure R2 has a sufficient power rating to safely carry the full load current Refer to DMS Application Note 6 for more information on dc ammeters 1 Install R2 R2 FSR IMAX x 10000 where FSR is the desired meter reading 0 up to 1999 disregarding any decimal point...

Page 5: ...This datasheet has been downloaded from www DatasheetCatalog com Datasheets for electronic components ...

Reviews: