Datel DMS-30PC Series Manual Download Page 2

2

Performance/Functional Specifications

Typical at T

A

 = +25°C and supply voltage = +5V using the single-ended input circuit,

unless otherwise noted.

DMS-30PC

3 ½   D I G I T ,   L E D   D I S P L A Y   D I G I T A L   P A N E L   V O L T M E T E R S

DMS-30PC - 1 - R S

LED Color:

AS = Standard Amber
BS = Standard Blue
GS = Standard Green
OS = Standard Orange
QS = Standard Aqua
RS = Standard Red
YS = Standard Yellow
RH = High-Intensity Red
GL = Low-Power Green
OL = Low-Power Orange
RL = Low-Power Red

Technical Notes

1. +1.23V REFERENCE OUTPUT (Pin 9):  This pin is the output of the

meter’s pre1.23V internal reference, and it is referenced to
ANALOG COMMON (pin 10) which sits at a potential of approxi-
2V.  This output should be buffered if used to drive external
loads since sourcing more than 15µA from pin 9 can affect both the
initial accuracy and temperature drift of the meter.

2. ANALOG COMMON (Pin 10):  This pin is connected to an internal,

low-noise, "relative" ground.  It is used in certain differential and
"floating" measurements as described in the Applications section of
this data sheet and Ap Note 3 of the DATEL Panel Meter Catalog.
Pin 10 should not be connected to pin 3 (5V RETURN) or to your
system’s analog ground.

3. REFERENCE OUTPUT (Pin 8) and INPUT (Pin 7): Pin 8 is a

precision reference actively trimmed at the factory.  In normal
operation, pin 8 must be tied to pin 7 to achieve all listed accuracy
and drift specifications.

Accessories:

DMS-30-CP

Panel cutout punch

DMS-BZL1

DMS-30 bezel assembly

DMS-BZL2

DMS-30 bezel assembly with sealing gasket

RN-DMS

Gain/offset potentiometer kit for DMS-EB,
DMS-EB-AC/DC and DMS-EB-DC/DC

Add-On Application Boards:

DMS-EB

Multi-purpose (gain/offset, 4-20mA, etc.)

DMS-EB-HTB

High-accuracy temperature probe sensing for

±200mV models

DMS-EB-DC/DC

Provides is5V power

DMS-EB-TCJ

J-type thermocouple inputs for ±2V models

DMS-EB-TCK

K-type thermocouple inputs for ±2V models

DMS-EB-RMS

For true rms measurements of ac voltages

DMS-EB-AC/DC

For ac line-powered applications

DMS-EB-LP

For 4-to-20mA loop-powered applications

Input Range:

0 = ±200mV
1 = ±2V
2 = ±20V

3 = ±200V Available on the

following models only:
-GS (Standard Green)
-RS (Standard Red)
-RL (Low-Power Red)

Ordering Information

Applies for transient or continuous overvoltages applied to (+) INPUT HI (pin 11)
with (–) INPUT LO (pin 12) properly connected. Pin 12 is not overvoltage protected
(see Figure 1). Voltages applied to pin 12 should not exceed the supply voltage.

See Technical Notes.

Analog Inputs

Min.

Typ.

Max.

Units

Full Scale Input Range:

DMS-30PC-0

--

±200

--

mV

DMS-30PC-1

--

±2

--

Volts

DMS-30PC-2

--

±20

--

Volts

DMS-30PC-3

--

±200

--

Volts

Input Impedance:

DMS-30PC-0, -1

100

1000

--

M

DMS-30PC-2, -3

0.8

1

--

M

Overvoltage Protection 

--

--

±250

Volts

Common Mode Voltage Range

--

--

±2

Volts

CMRR (dc to 60Hz)

--

86

--

dB

Control Inputs

 

Decimal Point Placement (Pins 4-6)

Tie to pin 3 to activate

Display Test  (Pin 2)

Tie to +5V to activate all segments

Performance

Sampling Rate

2.5 samples per second

Accuracy (3 minute warm-up):

DMS-30PC-0 (V

IN

 = +0.19V)

--

±1

±2

Counts

DMS-30PC-1 (V

IN

 = +1.9V)

--

±1

±2

Counts

DMS-30PC-2 (V

IN

 = +19V)

--

±2

±3

Counts

DMS-30PC-3 (V

IN

 = +190V)

--

±2

±3

Counts

Zero Reading (V

IN

 = 0 Volts)

"– 001"

"000"

"001"

Temperature Drift (0 to +60°C)

--

±0.15

±0.3

Cnts/°C

+1.23V Reference Output (Pin 9)

 ➁

+1.20

+1.23

+1.25

Volts

Power Supply Requirements

Supply Voltage

+4.75

+5.00

+5.25

Volts

Supply Current:

Standard Models:

Blue display

--

+400

+550

mA

All others

--

+150

+225

mA

Low-Power Models:

Red display

--

+12

+17

mA

Green or orange display

--

+60

+100

mA

Display

Display Type and Size

3½ Digit LED, 0.56"/14.2mm high

Polarity Indication

Autopolarity ("–" for negative V

IN

)

Overrange Indication

"–1_ _ _ " for negative V

IN

"1_ _ _ " for positive V

IN

Physical/Environmental

Operating Temperature:

Blue display models

0

--

+50

°C

All other models

0

--

+60

°C

Storage Temperature

– 40

--

+75

°C

Humidity (Non-condensing)

0

--

95

%

Case Material

Polycarbonate

Weight

0.75 ounces (21 grams)

A panel-mount retaining clip is supplied with each model.

Summary of Contents for DMS-30PC Series

Page 1: ...reference and is fully calibrated prior to potting We guarantee outstanding initial accuracy 1 count and excellent stability 0 15 counts C All models operate from a single 5V supply and the low power models draw as little as 10mA 50mW total power A DISPLAY TEST function is standard on each device For popular applications 4 to 20mA rms to dc conversion ac line power J and K thermocouples etc the DM...

Page 2: ... for 2V models DMS EB TCK K type thermocouple inputs for 2V models DMS EB RMS For true rms measurements of ac voltages DMS EB AC DC For ac line powered applications DMS EB LP For 4 to 20mA loop powered applications Input Range 0 200mV 1 2V 2 20V 3 200V Available on the following models only GS Standard Green RS Standard Red RL Low Power Red Ordering Information Applies for transient or continuous ...

Page 3: ... The multimeter s negative lead usually the black one must be connected to pin 3 5V RETURN 4 DISPLAYTEST Pin 2 Connecting pin 2 to 5V SUPPLY pin 1 will activate all LED segments except the decimal points and the display will read 1888 regardless of the actual applied input If a negative input is applied DISPLAY TEST will also activate the minus sign To protect the LED s the display should not be l...

Page 4: ...s 2 Differential Input Configurations Differential measurements can be made with all DMS 30PC meters Figure 3 though not a practical real world application uses a voltage divider to demonstrate the concept of a differential input signal Be careful not to exceed the 2V common mode voltage limitation for 5V powered meters 3 Engineering Scaling For measuring voltages greater than the full scale input...

Page 5: ...onsult the regulator manufacturer s data sheet to ensure the regulator is being utilized safely and correctly 7 Digital Ammeter Digital ammeters are finding ever increasing usage because analog style ammeters moving vane types now cost roughly the same as their digital counterparts Additionally analog ammeters are not nearly as rugged as modern digital panel voltmeters Figure 9 illustrates a typic...

Page 6: ... 0 025 0 635 NOMINAL RECOMMENDED PC BOARD FINISHED HOLE DIAMETER 0 042 0 003 1 067 0 076 Mechanical Specifications DS 0258D 1 98 MADE IN USA BEZEL INSTALLATION PANEL BEZEL RETAINING CLIP INSTALLATION PANEL 2 56 INSERT 0 156 3 96 DEEP FRONT VIEW 1 270 32 26 0 187 4 75 OPTIONAL BEZEL DMS BZL1 and DMS BZL2 2 35 59 69 2 118 53 80 0 093 2 362 DIAMETER 4 REQUIRED ONLY WHEN USING OPTIONAL BEZEL ASSEMBLY ...

Reviews: