Datecs Ltd.
www.datecs.bg
Page 13
PP-60 User Manual v1.0
Diagnostic Information
The PP-60’s FEED switch/button is used for entering various printer
modes. These modes can be used to assist developers in
debugging problems related to programming and communication.
The following explain how to access the various operating modes.
Step #1: Make sure the printer is OFF (BT LED is OFF) before
performing step #2 or step #3.
Step #2: Press and hold the Feed Button (FB). While pressing
the (FB) button, press the (POWER) button momentarily.
Step #3: Press and hold (POWER) button and release when one
of the conditions bellow.
Feed Button Operation Modes
Holding
Feed
button while power
on
for
~ 0.5
sec and releasing it
after
1-beep
.
SHORT
SELF TEST
print.
Holding
Feed
button while power
on
for
~ 2.5
sec and releasing it after
2-beep
.
Hex DUMP mode
. All
input data are printed as
hexadecimal.
Holding
Feed
button while power
on
for
~ 4.5
sec and releasing it after
3-beep
.
LONG
SELF TEST
print.
Holding
Feed
button while power
on
for more than
8.5
sec and releasing it after
the
5-beep 4-tone beep.
Program mode –
loading the printer
firmware.
Holding
Power
button while power
on
for
~ 4
sec and releasing it after
1-beep
.
Temporary forcing
9600 bps
serial speed or
clearing Bluetooth pair
info.
Holding
Power
button while power
on
for
~ 6
sec.
Hardware Setup Mode.
Table 5
Note:
Care must be taken when entering operating modes to prevent the