1 DATECS
DPP-350
Programmer’s manual VER.1.50
26
58.
Specifying relative horizontal position (
ESC \
)
Code:
[1Bh] + [5Сh] + n1 + n2
0 <=
n1
<= FFh Specifying number of dots from current position in horizontal (LSB).
0 <=
n2
<= FFh Specifying number of dots from current position in horizontal (MSB).
The printing start position is specified with
n1 + 256*n2
dots. Specifying exceeding the top of line or the
end of line is ignored.
Specifying dots in minus (left) direction from the current one, is the complement of N with 65536
(N
-
=65536 - N).
59.
Loading the default settings stored in Flash memory (
ESC ]
)
Code:
[1Bh] + [5Dh]
•
The following parameters are read from flash memory and become active:
•
Speed of communication in serial port
•
Time for automatic turn off
•
Configuration “switches”
•
Max printing speed
•
Print density
•
Height of printing line
•
Country
•
Code table
•
Height of barcode
•
Width of barcode single line
•
Font of the text (HRI characters) corresponding to the barcode
•
Position of the HRI characters
60.
Saving current settings in Flash memory (
ESC ^
)
Code:
[1Bh] + [5Eh]
•
The values of the following settings are stored in flash memory:
•
Speed of communication in serial port
•
Time for automatic turn off
•
Configuration “switches”
Max printing speed
•
Print density
•
Height of printing line
•
Country
•
Code table
•
Height of barcode
•
Width of barcode single line
•
Font of the text (HRI characters) corresponding to the barcode
•
Position of the HRI characters
These setting become default settings.
61.
Loading factory settings (
ESC
_
)
Code:
[1Bh] + [5Fh]
•
This command sets the printer in default state with the following settings:
•
All printing attributes like underline, rotating etc. are cleared.
•
Internal font A (12 x 24) is selected.
•
Pitch between lines is 1/6 inch.
•
Barcode height is 80 dots, and barcode width is 3.
•
All downloaded fonts and bit images are cleared.
•
Printing speed is set to 60 mm/s.