DT1300 xx xx xx
16
20171220-V0
7. Dismounting
7.1. Dismounting procedure
The following figure shows the dismounting procedures:
Dismounting from the
rail
The dismounting procedure needs a screwdriver for slotted
screws.
Pull out all the terminals:
1. Put the screwdriver into the slot between the terminal
and the housing (figure step 1.).
2. Lift (lower terminals) or push down (upper terminal) the
screwdriver handle as far as the terminals will be free
(figure step 2.).
Dismount the instrument:
3. Put the screwdriver end into the fixing assembly’s hole
(figure step 3.).
4. Lift the screwdriver handle until it possible to open the
fixing assembly (figure step 4.).
5. Keeping the screwdriver in this position lift the
instrument bottom from the bottom edge of the rail (figure
step 5.).