background image

 

FCC Compliance Statement 

This device complies with part 15 of the FCC rules. Operation is subject to the following two 

conditions: 

1.

 

This device may not cause harmful interference, and  

2.

 

This device must accept any interference received, including interference that may cause 

undesired operation. 

Warnings and Precautions 

1.

 

Read all of these warnings and save them for later reference. 

2.

 

Follow all warnings and instructions marked on this unit. 

3.

 

Unplug this unit from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. 

Use a damp cloth for cleaning. 

4.

 

Do not use this unit in or near water. 

5.

 

Do not place this unit on an unstable cart, stand, or table. The unit may fall, causing serious 

damage. 

6.

 

Slots and openings on the cabinet top, back, and bottom are provided for ventilation. To 

ensure safe and reliable operation of this unit, and to protect it from overheating, do not 

block or cover these openings. Do not place this unit on a bed, sofa, rug, or similar surface, as 

the ventilation openings on the bottom of the cabinet will be blocked. This unit should never 

be placed near or over a heat register or radiator. This unit should not be placed in a built-in 

installation unless proper ventilation is provided. 

7.

 

This product should only be operated from the type of power source indicated on the 

marking label of the AC adapter. If you are not sure of the type of power available, consult 

your Datavideo dealer or your local power company. 

8.

 

Do not allow anything to rest on the power cord. Do not locate this unit where the power 

cord will be walked on, rolled over, or otherwise stressed. 

9.

 

If an extension cord must be used with this unit, make sure that the total of the ampere 

ratings on the products plugged into the extension cord do not exceed the extension cord’s 

rating. 

10.

 

Make sure that the total amperes of all the units that are plugged into a single wall outlet do 

not exceed 15 amperes. 

11.

 

Never push objects of any kind into this unit through the cabinet ventilation slots, as they 

may touch dangerous voltage points or short out parts that could result in risk of fire or 

electric shock. Never spill liquid of any kind onto or into this unit. 

12.

 

Except as specifically explained elsewhere in this manual, do not attempt to service this 

product yourself. Opening or removing covers that are marked “Do Not Remove” may 

expose you to dangerous voltage points or other risks, and will void your warranty. Refer all 

service issues to qualified service personnel. 

13.

 

Unplug this product from the wall outlet and refer to qualified service personnel under the 

following conditions:

 

a.

 

When the power cord is damaged or frayed; 

b.

 

When liquid has spilled into the unit; 

c.

 

When the product has been exposed to rain or water; 

d.

 

When the product does not operate normally under normal operating conditions. Adjust 

only those controls that are covered by the operating instructions in this manual; 

improper adjustment of other controls may result in damage to the unit and may often 

require extensive work by a qualified technician to restore the unit to normal operation; 

e.

 

When the product has been dropped or the cabinet has been damaged; 

f.

 

When the product exhibits a distinct change in performance, indicating a need for service.

 

Summary of Contents for TLM-170G

Page 1: ...70G TLM 170GM TLM 170GR 17 3 3G SDI TFT LCD MONITOR Instruction manual MUTE POWER VOL MENU ENTER UP DOWN ASPECT PIP CV2 CV1 HDMI 1 HDMI 2 BLUE PATTERN S SDI YUV HEADPHONE 17 3 3G SDITFTLCDMONITOR TLM...

Page 2: ...nly At all times Datavideo Technologies will try to give correct complete and suitable information However Datavideo Technologies cannot exclude that some information in this manual from time to time...

Page 3: ...this unit where the power cord will be walked on rolled over or otherwise stressed 9 If an extension cord must be used with this unit make sure that the total of the ampere ratings on the products plu...

Page 4: ...rchase Certain parts with limited lifetime expectancy such as LCD panels DVD drives Hard Drive Solid State Drive SD Card USB Thumb Drive Lighting Camera module PCIe Card are covered for 1 year The thr...

Page 5: ...ystem Desktop 7U Rack Mount 1U Mobile Tray Rack Mount Front Panel Name Descriptions Bi Colour Tally Light To indicate Live Red or Cued Amber source Source Select Buttons Select SDI HDMI YUV or CV the...

Page 6: ...spect ratio of the source to fill the screen When viewing a 4 3 source in ZOOM mode on a 16 9 display the aspect ratio of the visible video will remain 4 3 though the entire 16 9 screen will be filled...

Page 7: ...be supplied to the TLM 170G from the Datavideo RMC 140 TB 5 or TB 10 via this socket Analog Audio Inputs Mono audio inputs to correspond to the analog video inputs CV 1 CV 2 Composite Video Inputs 1 2...

Page 8: ...LE ENABLE NR HIGH MID LOW OFF MPEG NR HIGH LOW OFF DLC DISABLE ENABLE VOLUME 0 100 EXIT 3D COMB is for video noise suppression NR is for video noise reduction MPEG NR is for MPEG format noise reductio...

Page 9: ...PLAY ON OFF TITLE POSITION MID TOP MID BOT FONT SIZE SMALL LARGE FONT COLOR RED GREEN ORANGE WHITE EDIT TITLE A Z EXIT SETUP NETWORK DHCP ON OFF User s choice IP 127 127 127 127 User defined assigned...

Page 10: ...nDisk 8G Cruzer Glide USB flash drive Transcend Jet Flash 16G Kingston DT101 G2 8GB FACTORY RESET Once in this option press ENTER button to reset the TLM 170G to factory default settings AUDIO CONTROL...

Page 11: ...USB 2 0 port labelled MAINTENANCE located on the rear panel of the TLM 170G monitor 5 Power on the monitor and press the MENU button to display the OSD Main Menu 6 Use the OSD Menu buttons UP DOWN ENT...

Page 12: ...ion DHCP to ON and press ENTER The same OSD menu screen will now show the IP address given by the network to the TLM 170G monitor Make a note of this displayed IP address 5 From a computer on the same...

Page 13: ...ring Center window on the Windows computer Open the Local Area Network Properties window and make a note of any displayed IP address or settings so you can return the computer back to its original set...

Page 14: ...14 Dimensions All measurements in millimetres mm...

Page 15: ...6M 1080P 60 59 94 50 SMPTE 125M 480I 59 94 ITU R BT 656 576I 50 Audio Input Composite x 2 YUV x 1 Audio Output Speaker cable output connections L L R R Max 5v p p 2w Speaker Output connections Max 5v...

Page 16: ...o in Tel 91 0120 2427337 A 132 Sec 63 Noida 201307 India India Noida Datavideo India Kochi Tel 91 4844 025336 Fax 91 4844 047696 2nd Floor North Wing Govardhan Building Opp NCC Group Headquaters Chitt...

Reviews: