39
Open the TLM-170F’s OSD menu to adjust the monitor’s
backlight value and click the
Update
button in the
Luminance Units
pane located at the top right of the
window above.
As soon as the
Update
button is clicked, the
Calibration
Status
window will appear along with the
Calibration Area
and
a dialogue box. Drag the
Calibration Area
to the TLM-
170F. Lastly, point the probe at the calibration area as
close as possible then click the
OK
button in the dialogue
box to start calibration.
Repeat the process until the
MAX
value in the
Luminance Units
pane is in the range of 80 – 120.
Note that the closer the MAX value to 100, the better the TLM-170F is calibrated
.
6.
Color calibration
On the Display Characterization window (
Tools
Calibration
Display Characterization
), slide
the
Select Cube Side
slider to 21 so that the Total Frames measured are 9261. Set
Patch Sequence
to
Sequential
and
Select Time per Frame
to
Closed Loop Mode
.
Summary of Contents for TLM-170F
Page 1: ...17 SCOPEVIEW PRODUCTION MONITOR Instruction Manual TLM 170F TLM 170FM TLM 170FR...
Page 46: ...46 6 Dimensions mm...
Page 49: ...49 Notes...
Page 50: ...50 Notes...
Page 51: ...51 Notes...