Page 1: ...ROBOTIC PTR 10T MARK II PAN TILT HEAD Instruction Manual ...

Page 2: ... 3 2 VIDEO 13 4 CONTROL FUNCTIONS 14 4 1 RS 422 VISCA COMMUNICATION PROTOCOL 14 4 2 DVIP 16 4 3 REMOTE OUT 18 Remote Port 18 LANC 18 BX Lens 20 RS 232 422 OUT 20 RS 232 20 RS 422 21 4 4 TALLY 21 4 5 IR REMOTE CONTROL 22 Function Descriptions 23 OSD Menu 26 5 DIP SWITCH 33 6 FIRMWARE UPDATE 33 6 1 FIRMWARE UPGRADE REQUIREMENTS 34 6 2 UPGRADE PROCEDURE 34 7 FREQUENTLY ASKED QUESTIONS 35 8 DIMENSIONS...

Page 3: ...mplete This manual may contain typing errors omissions or incorrect information Datavideo Technologies always recommend that you double check the information in this document for accuracy before making any purchase decision or using the product Datavideo Technologies is not responsible for any omissions or errors or for any subsequent loss or damage caused by using the information contained within...

Page 4: ...t should not be placed in a built in installation unless proper ventilation is provided 7 This product should only be operated from the type of power source indicated on the marking label of the AC adapter If you are not sure of the type of power available consult your Datavideo dealer or your local power company 8 Do not allow anything to rest on the power cord Do not locate this unit where the p...

Page 5: ...iod begins on the thirtieth day after shipment from a Datavideo office All non Datavideo manufactured products product without Datavideo logo have only one year warranty from the date of purchase Damage caused by accident misuse unauthorized repairs sand grit or water is not covered under warranty Viruses and malware infections on the computer systems are not covered under warranty Any errors that...

Page 6: ... collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste disposal service or the shop where you purchased the...

Page 7: ...Camera Controller RMC 300A Universal Remote Control Panel and is compatible with serial or Ethernet HDBaseT 1 1 Features Strong and sturdy aluminum frame Various interfaces SDI HDMI RS 232 RS 422 HDBaseT Tally and LANC Multiple controller choices RMC 180 RMC 300A RMC 300C HS 1600T and ShowCast 100 Built in tally light D tap connector for DC output Selectable DC voltage output 7 4 8 4 10 12 for dif...

Page 8: ...8 ...

Page 9: ...9 2 System Overview ...

Page 10: ...nt output voltages that the DC OUT D tap connector is delivering See the section on DIP Switch for selection of output voltage Video 4 SDI IN Video IN from the mounted camera 5 SDI OUT Delivers camera video to external devices such as a video switcher 6 HDMI IN Video IN from the mounted camera 7 HDMI OUT Delivers camera video to external devices such as a video switcher The OSD menu will overlay o...

Page 11: ...ra s zoom and focus as well as other functions See the REMOTE section for cable pinout information connection instructions as well as a list of compatible cameras Note A remote cable 8pin mini din to 2 5mm phone jack accompanying the PTR 10T MARK II is designed for connecting to various camera brands Warning The 8pin snap and lock mini din connector of the remote cable will be securely fastened on...

Page 12: ...12 Firmware Upgrade Device Configuration 16 F W Upgrade For upgrading to the latest firmware See Firmware Update 17 DIP Switch For configuring the PTR 10T MARK II See DIP Switch ...

Page 13: ...supplied 12V 5A PSU The connection can be secured by screwing the outer fastening ring of the DC In plug to the socket D tap DC OUT 24W The D tap connector supplies DC power to the camera 3 2 Video SDI HDMI IN Video IN from the mounted camera via SDI or HDMI interface SDI HDMI OUT Delivers camera video to external devices such as a video switcher via SDI or HDMI interface ...

Page 14: ...ee the diagrams below for example system setups RMC 180 Camera Controller RMC 300A Camera Controller To control the camera mounted on PTR 10T MARK II using the camera controller first connect one of the RJ 45 ports provided on the controller rear to PTR 10T MARK II s RS 422 IN port via an RJ 45 cable Then depending on the protocol used either connect PTR 10T MARK II to the camera via the Remote po...

Page 15: ... 422 IN GND 1 White Orange White Orange 1 GND NC 2 Orange Orange 2 NC TX 3 White Green White Green 3 RX RX 4 Blue Blue 4 TX RX 5 White Blue White Blue 5 TX TX 6 Green Green 6 RX NC 7 White Brown White Brown 7 NC NC 8 Brown Brown 8 NC Please note that bit 4 of the DIP switch on PTR 10T MARK II devices must be set to OFF prior to establishing physical connection See the DIP Switch section for detail...

Page 16: ...DBaseT The HDBaseT port allows you to connect an HDBaseT switcher via any standard Ethernet cables from which the PTR 10T MARK II device is controlled Before connecting set the DIP switch position 4 to ON first ...

Page 17: ...stance that the CAT 6 Ethernet cable is able to provide at different resolutions Resolution Transmission Distance Max 2160p30 70 m 1080p60 100 m In addition to HDBaseT switchers as illustrated in the system diagram below you can also connect multiple PTR 10T devices to an SE 500MU 4K switcher an RMC 180 camera controller and a PD 6 power center via HBT 11 HDBaseT receivers ...

Page 18: ...ort when connected to the camera mounted allows you to access certain functions of various camera brands such as ZOOM and FOCUS To use this function you will need to first enable LANC or BX Lens mode by accessing the OSD menu option Remote Out Mode on your PTR 10T MARK II device Follow the menu path below 4 Remote Control 6 Set Remote Out 1 Remote Out mode LanC or BX Lens LANC If the LANC mode is ...

Page 19: ...cally designed and manufactured the cable for such connection The part number of the remote cable is G07620000138 Model Brand Power Consumption DC Input Accessible Functions PXW Z280V Sony 24 31 W 12V Zoom Focus Iris OSD Menu OSD Display Shutter White Balance Mode Gain and ND PXW Z190V Sony 22 29 W 12V PXW Z150 Sony 6 3 6 6 W 8 4V PXW X160 Sony 19 9 20 8 W 19 5V HNR NX5R Sony 7 5 7 8 W 8 4V HNR NX...

Page 20: ... part number of the 8 pin to 8 pin remote control cable is G07620000133 See below for details Model Brand Power Consumption DC Input Accessible Functions PXW X200 X280 Sony 18 23 W 12V Zoom RS 232 422 OUT If either of the RS 422 and RS 232 modes of connection is selected in Remote Out Mode you may mount Datavideo s BC 80 or BC 200 on the PTR 10T MARK II and use a custom made RJ 45 cable to establi...

Page 21: ...X NC 7 White Brown White Brown 7 NC NC 8 Brown Brown 8 NC 4 4 Tally Two tally sockets can be found on your PTR series device Tally IN receives tally information from external devices such as a video switcher Tally OUT delivers tally information to the mounted camera Tally Light Definitions Message On Air Live Standby Cued Free Safe Light Red Green No Light A simple test tool is illustrated in the ...

Page 22: ...22 4 5 IR Remote Control Operates PTR 10T MARK II by an IR remote control ...

Page 23: ...esets allowing automatic movement of cameras to these positions in the order configured in the group Recalling Group The PTR 10T MARK II is equipped with 8 groups To recall a group first press the number keys to select a group number 1 8 then press the GROUP button to enable it Saving Group Settings To configure the group setting first open the OSD menu then select MEMORY Each group allows you to ...

Page 24: ...ESET button description Set up Group Scan mode Press any of the group numbers 1 8 and then press the GROUP button see the GROUP button description Return Camera Lens to the Front Press number 0 and then press PRESET button 6 Focus Setup Manually focus camera lens on a subject Press either F FAR button or N NEAR button to manually focus the camera lens onto the subject 7 Auto Focus Control Automati...

Page 25: ...ow less light to come in so that the subject appears less bright To cancel the function or return to default setup press the Auto button 11 ENTER ENTER Menu ENTER key 12 Direction Arrows Change camera direction Press arrow buttons to change the direction of the camera head Stop Preset Point Auto Scan mode Press any of the DIRECTION buttons Select Menu Option Press UP or DOWN arrow button to select...

Page 26: ...ain to wake the device from standby mode OSD Menu The OSD menu allows you to modify various device settings such as pan and tilt and control protocols Press the menu button on your remote control opens the OSD menu shown below The table below summarizes the main option items and their sub options Main Options Set Motor Memory Video Mode Remote Control System Reset P T Escape Sub Options 1 P T Acce...

Page 27: ...roup 7 8 Escape 9 Tilt Min Limit 9 Group 8 10 Tilt Max Limit 10 Escape 11 Escape Details of all options in the on screen menu are listed in the table below First Level Main Options Second Level Sub Options Third Level Parameters Fourth Level Parameters Sub Option Description 1 Set Motor 1 P T Acceleration Fast Middle Slow 2 P T Speed Auto Speed Normal 3 PAN torque ADJ LOW 1 5 4 TILT torque ADJ LOW...

Page 28: ...LT Max Limit 45 1 11 Escape 2 Memory 1 Preset Position 1 50 P T 1 P T Speed 1 18 2 Escape 51 ESCAPE 2 Group 1 1 16 PRESET NO 1 50 ITEM ON OFF ON OFF SPEED LIMIT 1 18 WAITING TIME 0 180 NEXT POSITION NEXT ITEM RETURN GROUP 1 GROUP 2 GROUP 3 GROUP 4 GROUP 5 GROUP 6 GROUP 7 GROUP 8 ESCAPE 17 ESCAPE 3 Group 2 1 16 PRESET NO 1 50 ITEM ON OFF ON OFF SPEED LIMIT 1 18 WAITING TIME 0 180 NEXT POSITION NEXT...

Page 29: ...ME 0 180 NEXT POSITION NEXT ITEM RETURN GROUP 1 GROUP 2 GROUP 3 GROUP 4 GROUP 5 GROUP 6 GROUP 7 GROUP 8 ESCAPE 17 ESCAPE 5 Group 4 1 16 PRESET NO 1 50 ITEM ON OFF ON OFF SPEED LIMIT 1 18 WAITING TIME 0 180 NEXT POSITION NEXT ITEM RETURN GROUP 1 GROUP 2 GROUP 3 GROUP 4 GROUP 5 GROUP 6 GROUP 7 GROUP 8 ESCAPE 17 ESCAPE 6 Group 5 1 16 PRESET NO 1 50 ITEM ON OFF ON OFF SPEED LIMIT 1 18 WAITING TIME 0 1...

Page 30: ... 1 18 WAITING TIME 0 180 NEXT POSITION NEXT ITEM RETURN GROUP 1 GROUP 2 GROUP 3 GROUP 4 GROUP 5 GROUP 6 GROUP 7 GROUP 8 ESCAPE 17 ESCAPE 8 Group 7 1 16 PRESET NO 1 50 ITEM ON OFF ON OFF SPEED LIMIT 1 18 WAITING TIME 0 180 NEXT POSITION NEXT ITEM RETURN GROUP 1 GROUP 2 GROUP 3 GROUP 4 GROUP 5 GROUP 6 GROUP 7 GROUP 8 ESCAPE 17 ESCAPE 9 Group 8 1 16 PRESET NO 1 50 ITEM ON OFF ON OFF SPEED LIMIT 1 18 ...

Page 31: ...Size 1280 x 720 1920 x 1080 3840 x 2160 3 HDMI Mode RGB444 YUV422 4 Escape 4 Remote Control 1 PAN TILT Reverse OFF P T P T 2 Remote Source RS 422 SW Configurable using bottom DIP switch ONLY 3 Set RS 422 CAMERA ID MODE BY MENU BY SWITCH CAMERA ID 1 7 RS 422 BAUD RATE 9600 19200 38400 115200 Recall s Response Tailer Leader ESCAPE 4 Set DVIP DVIP BAUD RATE 9600 19200 38400 115200 ESCAPE 5 Set IR IR ...

Page 32: ... Display P T OSD PAN OSD ON OFF TILT OSD ON OFF VZOOM OSD ON OFF ESCAPE DEBUG OSD DEBUG IR OSD ON OFF DEBUG RS 422 OSD ON OFF DEBUG DVIP OSD ON OFF DEBUG M_CTL OSD ON OFF DEBUG REG OSD ON OFF DEBUG FRAME NO ON OFF ESCAPE ESCAPE 2 Tally Light RED GREEN GREEN RED OFF 3 Model No 0150 0010 4 Reset All YES NO 5 Update Software SW VERSION ESCAPE MB CPU V00 49a MCTL CPU V00 31 UPDATE ALL YES NO ESCAPE 6 ...

Page 33: ...itch can be found on one of the system panels and allows the user to set the device s VISCA ID enable remote control HDBaseT or RS 422 configure the OSD menu size and select the DC output See the table below for various settings ...

Page 34: ...rocedure 1 Copy firmware image files MB and MCTL into the root directory of a USB hard drive 16 GB and insert it into the F W Upgrade USB port 2 Use the IR remote control to open the OSD menu Note If you are using more than one camera in your environment first select the camera by pressing the corresponding CAM button the default is CAM1 3 Main Menu 5 SYSYEM 5 UPDATE SOFTWARE UPDATE ALL YES ENTER ...

Page 35: ... overloaded the device power will be automatically disconnected To resume power first turn off the device unplug the power cable for more than 15 seconds then reconnect the power and turn on the device 2 DC Out does not supply power Once the short circuit protection is activated to cut the power you will need to reboot the device to resume supplying power to the camera 3 How to prevent activation ...

Page 36: ...36 8 Dimensions PTR 10T MARK II All measurements in millimeters mm ...

Page 37: ...ocol Controller IP Control IR Remote Pan Tilt Range PAN 340 MAX TILT 45 to 45 MAX Pan Tilt Speed PAN 0 2 15 Sec TILT 0 1 10 Sec Presets 50 PAN TILT positions Control Distance RS 422 1200 m HDBaseT 100 m Control Protocol Sony VISCA DVIP Control Interface RS 422 HDBaseT Control Output RS 232 RS 422 BX Lens Lanc Maximum Load 4 0 Kg Max Power Requirement DC 12V 18V 3A Without Camera DC 12V 18V 5A With...

Page 38: ...38 Storage Temp 10 60 C Storage Humidity 5 80 Weight 3 4 Kg Dimensions LxWxH 230 x 190 x 300 mm Optional Accessories ZEK 1 WM 10 WM 11 CM 10 ...

Page 39: ...39 Notes ...

Page 40: ...Jan 10 2021 Version E1 Datavideo Technologies Co Ltd All rights reserved 2020 www datavideo com product PTR 10T MARK II ...